Table 5-80 – Maxtor ATLAS 10K III User Manual

Page 128

Advertising
background image

SCSI Description

5-64

Maxtor Atlas 10K III

 +PHQTOCVKQP 'ZEGRVKQPU %QPVTQN 2CIG %J

This page defines the methods used by the disk drive to control the reporting and
operations of specific informational exception conditions. This page applies only to
informational exceptions that report an additional sense code of FAILURE
PREDICTION THRESHOLD EXCEEDED to the application client.

Informational exception conditions occur as the result of vendor-specific events
within a disk drive. An informational exception condition may occur asynchronous to
any commands issued by an application client.

The data format and field descriptions are described in Table 5-80 and Table 5-81
respectively. The Codes Used by the MRIE Field are described in Table 5-82.

Table 5-80

Information Exceptions Control Page-(Page 1Ch)

$KV

$[VG

















0

PS

Page Code (1Ch)

1

Page Length (0Ah)

2 Perf

Reserved

EWASC

DExcpt

Test

Rsv’d

LogErr

3 Reserved

MRIE

4 - 7

(MSB)

Interval Timer

(LSB)

8 – 11

(MSB)

Report Count

(LSB)

Advertising