Table 5-154, Reassign blocks defect descriptor-data format -121 – Maxtor ATLAS 10K III User Manual

Page 185

Advertising
background image

SCSI Description

Maxtor Atlas 10K III

5-121

Table 5-154

REASSIGN BLOCKS Defect Descriptor-Data Format

The drive returns a CHECK CONDITION status if it cannot complete the
command. If this happens because the drive ran out of spare sectors, the drive sets the
sense key to MEDIUM ERROR and the additional sense code to NO DEFECT
SPARE LOCATION AVAILABLE. The sense key and additional sense key are set
appropriately for any other cause. The Logical Block Address of the first defect
descriptor not reassigned is returned in the command-specific information field of the
sense data. If all defects were reassigned, but some other error occurred, then
FFFFFFFFh is posted in the command-specific field.