9 electromagnetic conditions, 1 emi/rfi susceptibility, 2 sensitivity to magnetic fields – Maxtor ATLAS 10K III User Manual
Page 61: 9 electromagnetic conditions -9
Advertising
Specifications
Maxtor Atlas 10K III
4-9
'.'%641/#)0'6+% %10&+6+105
'/+4(+ 5WUEGRVKDKNKV[
5 Volts/meter @ 100 MHz.
The drive functions normally when any exposed metal is subjected to
electrostatic discharge excluding the PCB. This electrostatic discharge must be at
a minimum interval of 30 seconds, either from a 150pF capacitor discharged
through a 150K
Ω
resistor or from a 100pF capacitor through a 500k
Ω
resistor.
5GPUKVKXKV[ VQ /CIPGVKE (KGNFU
The Maxtor Atlas 10K III family of drives meets all specifications with a 6 gauss
field applied in any environment at 100 kHz.
0 – 5kV
Average of <0.3 soft errors per discharge
5 – 10 kV
Average of <1.0 soft errors per discharge
10 – 20 kV
No permanent degradation
Advertising