Lonworks interface product manual (sha-ln16uab), Indoor unit enabling switches, Address switches – Sanyo CHX06052 User Manual

Page 145: Setting switches, Communications led (green), Data led (red), Diagram of external dimensions, Product specifications, Remote control functions

Advertising
background image

2-127

Remote Control Functions

7. LonWorks Interface product Manual (SHA-LN16UAB)

2

One main cir c uit board can co ntrol 4 groups (indoor unit group s 0

– 3).

Set to “disable” if the indoor unit group do es not exist. Set to

“enable” if the indoor unit group exists.

Indoor Unit Enabling Switches

OFF

1 2 3 4

Address s w itc h

1

2

3

4

5

6

Cent ral c o ntr o l

addr es s

-

-

-

O

-

-

-

O

-

O

O

-

-

-

-

-

-

-

-

-

-

-

-

-

1
2
3
4

-

O

-

-

5

O

O

-

-

6

-

O

O

-

-

7

O

O

O

-

-

-

-

-

-

-

-

8

-

O

-

9

O

O

-

10

-

O

O

-

11

O

O

O

-

-

-

-

-

-

-

-

-

-

-

12

-

O

O

-

13

O

O

O

-

14

-

O

O

O

-

15

O

O

O

O

-

-

-

-

-

-

-

16

-

O

-

17

O

O

-

18

-

O

O

-

19

O

O

O

-

-

-

-

-

-

-

-

-

-

-

20

-

O

O

21

O

O

O

22

-

O

O

O

23

O

O

O

O

-

-

-

-

-

-

-

-

-

-

24

-

O

O

-

25

O

O

O

-

26

-

O

O

O

-

27

O

O

O

O

-

-

-

-

-

-

-

28

-

O

O

O

-

29

O

O

O

O

-

-

-

30

-

O

O

O

O

-

31

O

O

O

O

O

-

32

-

-

O

33

O

-

O

34

-

O

-

O

35

O

O

-

-

-

-

-

-

-

-

-

-

-

O

36

-

O

-

O

37

O

O

-

O

38

-

O

O

-

O

39

O

O

O

-

-

-

-

-

-

-

O

40

-

O

-

O

41

O

O

-

O

42

-

O

O

-

O

43

O

O

O

-

-

-

-

-

-

-

O

44

-

O

O

O

45

O

O

O

O

46

-

O

O

O

O

47

O

O

O

O

-

-

-

-

-

-

O

48

-

-

O

O

49

O

-

-

-

O

O

50

-

O

-

O

O

51

O

O

-

-

-

-

-

O

O

52

-

O

-

O

O

53

O

O

-

O

O

54

-

O

O

-

-

-

O

O

55

O

O

O

-

O

O

56

-

-

O

O

O

57

O

-

-

-

O

O

O

58

-

O

-

O

O

O

59

O

O

-

O

O

O

60

-

-

O

O

O

O

61

O

-

O

O

O

O

62

-

O

O

O

O

O

63

O

O

O

O

O

O

64

Address Switches

1 2 3 4 5 6

OFF

OFF

1 2 3 4 5 6 7

6

-
-
-
-

O
O
O
O

R / C pr ohi bi t

R / C pr ohi bi t

R / C pr ohi bi t

Fan sp ee d

Fan sp ee d

Ai r di r e cti on

7

-
-

O
O

-
-

O
O

8

-

O

-

-

O

-

–––

O

Option 1

Fan sp ee d

A i r d i re ct io n

Filte r sign

A i r d i re ct io n

Filte r sign

Filte r sign

Option 2

Setting Switches

O : ON - : O FF

Not used (Be sure to set to O FF.)

Not used (Be sure to set to O FF.)

OF F Communicate as a “sub” c entral control dev ice.

ON Communicate as a “main” central control de vice.

If ther e ar e n o centr al contro l devi ces oth e r than th is

interf ace , se t to “ m ain” (ON).

To set this in terface as the main, set on ly node 0 to

“main” (ON).

If using in co m b ination wi th a n com m unicatio n adap ter ,

AMY adapter , inte llig ent c ontroller , or s y ste m

controller, set to “sub” (OFF).

If using in combination wi th an ON/OFF c entral

controll er, s e t t h e ON/OF F central con t roll er as the

m a in if

th e

ON/OFF centr al

co ntroller’s

remote-controller prohibit function is to b e used . If this

interf ace’s rem o te-cont roll er pro h ibit funct i on is to be

used , set th is int e rfac e as th e m a i n .

OFF Cen t ral / i n d i vidual sett i n g i s accordi ng t o t h e cent ral

cont rol devi c e (normal set t i ng).

ON Cent ral / i ndi vi d ual set t i ng i s al ways set t o “i nd i v i dual . ”

OF F Indoor unit grou p 3 is di sable d .

ON Indoor u n it grou p 3 is e nabl ed.

OF F Indoor unit grou p 2 is di sable d .

ON Indoor u n it grou p 2 is e nabl ed.

OF F Indoor unit grou p 1 is di sable d .

ON Indoor u n it grou p 1 is e nabl ed.

OF F Indoor unit grou p 0 is di sable d .

ON Indoor u n it grou p 0 is e nabl ed.

OFF Cont rol t e mp erat ure i s used f o r t he room t e mperature

(normal set t i ng).

ON In le t te m perature i s used f o r t he ro om t e m perat ure.

O

: ON –: OFF R/C: Remote Controller

v

v

v

v

v

v

–––

–––

–––

LD001 LD002

Display meaning

X

X

Power OFF

X

Low

X

High

Flash writer writing in progress

X




–––––




O

Waiting for A/C unit initial communication

Low

X

A/C unit initial communication in progress

Low

Low

Low

High

LonWorks communication microcomputer error

Lo




–––––




w

O

EEPROM error

High

High

High

High

X

Low

High

O






–––––

–––––

–––––

–––––

O

X

Test run mode

O

Low

O

High

Version display in progress

O




–––––




O

Normal communications in progress

X: Not lit、Low: Low-speed flashing (once/second)

High: High-speed flashing, O: Constantly lit

Communications LED (Green)

COM

1

2

Communications

LED

Data LED display meaning

No LED lit

All LEDs lit

–––––

–––––

–––––

–––––

–––––

–––––

–––––

Displays the wait time (seconds) for A/C

unit initial communication.

Displays the A/C unit communications status

No LED lit

No LED lit

According to the test run mode specifications

According to the version display specifications

Displays the A/C unit communications status

Data LED (Red)

Data

3 4 5 6 7 8

Display of A/C unit communications status

LD

Display meaning

Indoor unit

group

003

0

004

1

005

2

006

3

OFF:

Waiting for initial communication

Low-speed flashing:

Waiting for minimum

transmission interval

High-speed flashing:

Initial communication in

progress

ON:

Normal communications in progress

007

Illuminates for 200 ms when data is output to the

LonWorks communicator.

008

Illuminates for 200 ms when data is output to the

indoor/outdoor communicator.

Diagram of External Dimensions

Connects to LonWorks network

FTT-10 A transceiver device

Power

Single-phase, AC 100-120V or 200-240V

Power

consumption 11 W max.

Service

environment

conditions

External

dimensions

Height × Width × Depth

3-7/64 (in.) × 19-11/16 (in.) × 8-15/32 (in.)

Weight

Approx. 7.28 lb (3.3 kg)

Product Specifications

19-11/16

8-15/32

3-7/64

LD

LD

(in.)

COM: Communications

Temp. 32-104°F (0-40°C), humidity 20 to 80%

Indoor use only




















v