Timer remote controller (rcs-tm80bg), Ntest run function – Sanyo CHX06052 User Manual

Page 60

Advertising
background image

2-42

Remote Control Functions

3. Timer Remote Controller (RCS-TM80BG)

N

Test Run Function

Operates the unit with the thermostat forced ON.

<Procedure>

Press and hold the

button for 4 seconds or

longer.

“Test” appears on the remote controller LCD

display.

Start operation.

Press the

button to return to normal remote

controller display.

2

1 4

3

<Description>

N

Calling the Sensor Temperature Display

From the remote controller it is possible to engage

service monitor mode to determine the temperature

at the remote controller, indoor unit, and outdoor unit

sensors.

<Procedure>

Refer to the remote controller display.

Press and hold the

(CANCEL) and

(TEST/CHK) buttons simultaneously for 4 sec-

onds or longer to engage service monitor mode.

The service monitor illuminates. Initially, the main

indoor unit No., and the temperature for item

code

, are displayed.

Press the temperature setting

/

buttons to change the sensor number (item code)

to the sensor you wish to monitor. The sensor

numbers are listed on table 1 (below).

Press the

(UNIT SELECT) button and

change to the indoor unit that you wish to monitor.

The sensor temperatures of the indoor units

under group control and the corresponding out-

door unit are monitored.

Press the

(TEST/CHK) button to return to

normal display.

Display shows a discharge temperature of 85°C
at unit No. 1-1

4

3

2

1

Indoor

Unit

Data

Outdoor

Unit

Data

Item code

Data name

00

01

02

03

04

05

0A

0b

0C

0d

0E

11

Room temperature (control in effect) *

Room temperature (remote controller)

Indoor suction temperature

Indoor heat exchanger temperature (E1)

Indoor heat exchanger temperature (E3)

06

Discharge Air temperature (BL)

08

Position of Indoor unit Motor Operated Valve (MOV)

Discharge temperature (TD)

Suction temperature (TS)

Outdoor heat exchanger temperature (C1)

Outdoor Air temperature (TO)

* Main unit only in the case of group control

Table 1

Sensor Temperature Display

Procedure:

Returns to normal display.

1

2

3

4

1

4

3

2

NOTE

The temperature on the remote controller is
displayed in Celsius (C).
Please note that you will not mistakenly read it in
Fahrenheit (F) on the display.
Returns to normal display.

MiniECO-i.indb 42

2007/06/20 16:28:56