Remote sensor (art-k45agb), Parts supplied with remote sensor, Remote sensor installation guidelines – Sanyo CHX06052 User Manual

Page 156: How to install the remote sensor

Advertising
background image

2-138

Remote Control Functions

8. Remote Sensor (ART-K45AGB)

1. Parts supplied with remote sensor

No.

Qty

1

2

2

3

2

Machine screws

M4 × 25

(mm)

4

2

5

2

7

6

1

1

1

Spacers

Wire joints

Remote

Installation manual

(comes with 7 - 7/8" wire)

2. Remote sensor installation guidelines

Place of installation

• Mount the remote sensor at a height of 3 - 9/32 to 4 - 59/64 ft. above the floor

where it can sense the average temperature of the room.

• Do not mount the remote sensor in a place exposed to direct sunlight or a place

exposed to outside air such as near a window.

• Do not mount the remote sensor behind an object so that it is separated from the

air circulation of the room.

• Mount the remote sensor within the room being air conditioned.

• The remote sensor must be mounted on the wall or other surface vertically.

Supplied parts

Clamp

Wood screws

1. Insert a screwdriver or the like in the groove on the lower side of the remote

sensor body to pry off the back case. (See Fig. 2-7)

2. Use the 2 supplied M4 machine screws to secure the remote sensor back case.

Prior to mounting, clear the cutouts in the back case corresponding to the
holes in the wall box using a screwdriver or the like. Use the spacers and take
care not to tighten the screws excessively. If the back case will not seat well,
cut the spacers to a suitable thickness.

3. Connect locally supplied 2 core lead wires to the lead wires from the remote

sensor. (See “How to wire the remot e sensor.”)

When connecting the locally supplied 2 core lead wires to the terminal
block, check the terminal numbers in the indoor unit to make sure that
the wires are correctly connected. (See Fig. 2-8)

(The remote sensor is damaged if 208 / 230V AC is applied.)

4. Fit the remote sensor to the tabs of the back case and mount it.

(Fig. 2-7)

3. How to install the remote sensor

< NOTE 1 > Do not twist the remote sensor wiring with the power wiring or run

it in the same metal conduit, because this may cause malfunction.

< NOTE 2 > Install the remote sensor away from sources of electrical noise.

< NOTE 3 > Install a noise filter or take other appropriate action if electrical

noise affects the power supply circuit of the unit.

Use an electric junction box (supplied locally) (See Fig. 2-6) for flush mounting of

the remote sensor.

(Fig. 2-6)

Simplified remote controller

Under case (back case)

Spacer

Machine screws
M4

s

25 (2) (mm)

Electric junction box
for one box (no cover)

Wall

MiniECO-i.indb 138

2007/06/20 16:31:19

Advertising