F-53

TROUBLESHOOTING & REPAIR

F-53

TEST PROCEDURE

1. Remove input power to the NA-5

2. Using the 5/16" nutdriver open the

control box PC board access door.

3. Locate the voltage PC board.

Jumper together the "BYPASS" and
“Common” pins on the NA-5 voltage
PC board. See Figure F.6 (On older
voltage boards these pins may be
labeled "B"). This should disable the
shut down circuit.

4. Connect to a Lincoln Electric CV

power source per connection dia-
gram. See the

Installation section

of this manual.

OUT OF VOLTAGE RANGE SHUT DOWN TEST

(Continued)

NA-5

FIGURE F.6 VOLTAGE BOARD AND PIN LOCATIONS

NA-5

VOL

T

AGE

G1556-[ ]

BYP

ASS

COM

AUT

O

JUMPER

TOGETHER

1/8 AMP FUSE