G-2

ELECTRICAL DIAGRAMS

NA-5

Wiring Diagram

1553

8-24-84H

11-14-86L

7-19-91J

7-10-92B
5-19-95D

1-12-96D

7-12-96P



NA-5

WIRING DIAGRAM

DAD

NONE

1553

8-1-80

5-8-92

G1512

t

UNLESS OTHERWISE SPECIFIED TOLERANCE

ON HOLE SIZES PER E2056
ON 2 PLACE DECIMALS IS .02

WITH PUBLISHED STANDARDS.

ON 3 PLACE DECIMALS IS .002
ON ALL ANGLES IS .5 OF A DEGREE

MATERIAL TOLERANCE (" ") TO AGREE

THE LINCOLN ELECTRIC CO.

CLEVELAND, OHIO U.S.A.

EQUIP.

TYPE

SCALE

DR

DATE

CHK

REF.

SUBJECT

SUP'S'D'G

SHT.
NO.

THE LINCOLN ELECTRIC CO.

THIS SHEET CONTAINS PROPRIETARY INFORMATION

OWNED BY

AND IS

NOT TO BE REPRODUCED, DISCLOSED OR USED

THE LINCOLN ELECTRIC CO.

G

G

WITHOUT THE EXPRESS PERMISSION OF

DIGITAL METER

VOLTMETER BOARD

SPEED-
METER

BOARD

510

519

602

601

2 5 3 4

1

6

518

510

517

510P

602

601

510P

510P

602

601

510

510

519

510P

602

601

DIGITAL METER

2 5 3 4

1

6

WORK

WELDING

NOZZLE

ARM.

ELECTRODE

BLUE

BLACK

WHITE

RED

541

539

626

627

67

525A

555

510A

TACH.

PICK-UP
P.C. BD.

CONTROL

POWER

SOURCE

A

B
C

87

531

GND

A

B
C

D
E
F

541
539

627

626

67

A

B
C

D

MOTOR RECEPTACLE

525A

555

510A

A

B
C

D
E
F

TACH. RECEPTACLE

G
H

I

2

4

31
32
21

A

B
C

GREEN

531

87

FLUX OR WATER

SOLENOID

INPUT RECEPTACLE

S12778
S12515
S12514
S12515
S13161-052
S13161-5/64
S14904(OUTER)
S14905(INNER)
S12514
S14904(OUTER)
S14905(INNER)

57F

57/1

57

57/1

95

95/1

95S

95/1

142

142/1
142/1

142T

SINGLE .035-.052
SINGLE 1/16-3/32
SINGLE 3/32-5/32
SINGLE 1/16-3/32
TWIN .045-.052

SINGLE 3/32-7/32

TWIN 3 32

/

TWIN 1/16-5/64

TWIN 5/64-1/8

40-778 I.P.M.
38-762 I.P.M.
22-428 I.P.M.
23-456 I.P.M.

15-289 I.P.M.

15-300 I.P.M.

PIN RATIO PART NUMBER RANGE RANGE

USE OF PIN "S" JUMPER CONNECTION.

541

539

627

87

32

531

532

531B

31

RF BYPASS

P.C. BOARD

621

87

667

531

626

WHITE

627

626

610

681

500

500

528

689

+

-

2
5
1
6
3
4

532
531A
631
610
531B
500

1/2A SLOW BLOW

POWER P. C. BOARD

POWER FUSE

1/2A SLOW BLOW

FIELD FUSE

539

627

541

626

1
2
3
4
5

6

528

500

CR4

COUPLED

MAGNETICALLY

ELECTRODE CABLE

TO POWER SOURCE

REED SWITCH ACTUATED BY

WELDING CURRENT

*

*

2

4
8

6
3
7

9
5

1

587
525
510

540

500

525

510
500
500

*

ORANGE

ORANGE

RED

WHITE

RED

TS2

528

ELECT

67

TS1

500

WORK

21

531A

R1

631

531B

POLARITY CONNECTIONS WHICH MATCH ELECTRODE AND WORK CABLE POLARITY CONNECTIONS TO POWER SOURCE.

HI-FREQUENCY INSTALLATION INSTRUCTIONS FOR REQUIRED #67 ELECTRODE VOLTAGE SENSING LEAD CONNECTION.

NOTE: NA-5 MOTORS INSULATED FOR HIGH FREQUENCY STARTING DO NOT HAVE THIS CONNECTION. REFER TO

"COM" TAB, UNLESS SPECIFIED ON THE POWER SOURCE CONNECTION DIAGRAM TO BE CONNECTED TO THE "AUTO" TAB

TO DISABLE THE "COLD" STARTING FEATURE.

AND TAPED CONNECTION

532

531

531A

CB1

500

500

528

689

621

667

TERMINAL

STRIP JUMPER

CIRCUIT
POLARITY

TERMINALS

610

R

ELECTRODE

500

*

*

682

681

585

610

2

LOGIC

P.C. BOARD

*

*

BLUE BLUE

WHITE

RED

RED

BLUE

BLUE

YELLOW

YELLOW

BLACK

BLACK

601

602

T1

587

ORANGE

ORANGE

BROWN

BROWN

T2

500

12

540

10

525

9

510

14
13

628

1

520

8

510P

7

510P

METER

6

632

2

512

3

511

5

511A

4

510P

15

586

11

*

CONTROL
P.C. BOARD

F

S

555

510A

525A

VOLTAGE P.C. BOARD

516

9

514

2

635

4

564A

510P

8

10

525

3

510

7

500

6
5

530

1

667

11

621

12

6

A

B

4

C

5

592

3

687

2

688

1

3

531B

8

532

9

637

4

511

1

511A

2
7

500

6
5

*

FAST BLOW

FUSE

1 8 AMP

/

S

F

*

B

D

A

*

BYPASS

COM

AUTO

*

4

2 1 3

688

688A

525

500

FILTER P.C. BOARD

LEAD PLUG

500

500

560

1

564

2

500

3

515

4

635

5

520

6

632

7

510P

8

9

W
W

10

564A

11

114A 12

*

PROCEDURE KIT

RECEPTACLE

JUMPER PLUG

ELECTRICAL SYMBOLS PER E1537

CAVITY NUMBERING SEQUENCE

*

N.M.

N.L.

N.E.

563

N.N.

1

584C

2

564
583S

4

5

500

6

515

3

500

1
5
4

6
3

589

581

1

582

4

628

2

530

3

687

5

688

6

5

563

9

563

6

561

8

560

7

588

4

584S

3

566

2

565

1

583C

4

3

2

1

5

6

637

528

586

587

592

689

*

REMOTE INTERFACE
MODULE (OPTIONAL)

COM

COM

UP

DOWN

START

STOP

SWITCHES

RED

RED

N.L.

24V.

SIGNALS

*

1

6

5
4
2
3

581A

500
586
592

582
515

N.F.

WHITE

WHITE

RED

RED

N.D.

N.H

FLUX RECEPTACLE

J4

A

B
C

GND

D

532

25

531

J3

J2

J1

WORK CABLE TO

POWER SOURCE

TS

3

N.K.

N.J.

5A CIRCUIT

BREAKER

25

TRAVEL SW.

S2

532

531

31

32

POWER SW.

S1

"HOT" LIGHT

LT1

DOWN

592

500

S4

INCH

UP

S3

586

500

625

N.A. SPEEDMETER BOARD CALIBRATION JUMPER IS TO BE CONNECTED FOR NA-5 HEAD AND DRIVE ROLL

EMPLOYED PER CHART BELOW: (CONNECTED TO PIN "95" OR "21" WHEN SHIPPED.

21

21/1

S12778

SINGLE .035-.052

100-2070 I.P.M.

= EARLIER SPEEDMETER BOARDS DID NOT HAVE THESE PINS.
= SINGLE "21" PIN ON HIGH SPEED BOARD ONLY.

N.B. REMOVE START RECEPTACLE JUMPER PLUG FROM PROCEDURE BOARD TO INSTALL OPTIONAL PROCEDURE

MODULE AS START PROCEDURE CONTROL. IF MODULE IS REMOVED, REPLACE JUMPER PLUG.

N.C. REMOVE CRATER RECEPTACLE JUMPER PLUG FROM PROCEDURE BOARD TO INSTALL OPTIONAL PROCEDURE

MODULE AS CRATER PROCEDURE CONTROL AND CONNECT LOGIC BOARD LEAD #694 TO PIN #P10.

IF MODULE IS REMOVED, REPLACE JUMPER PLUG AND LOGIC BOARD LEAD #694 TO PIN #P8.

N.D. CONTROL BOARD JUMPER LEAD CONNECTED TO PIN "F" WHEN SHIPPED. SEE OPERATING MANUAL FOR

N.E. VOLTAGE BOARD RED JUMPER LEAD CONNECTED TO PIN "S" AND WHITE JUMPER LEAD CONNECTED TO

N.G. 531-532 115VAC

531-25 115VAC (SWITCHED)

250 VAC

N.J. CONNECT #67 BLACK (ELECTRODE) LEAD AND #21 WHITE (WORK) LEAD TO APPROPRIATE TERMINAL STRIP

N.K. LEAD CONNECTED TO MOTOR FRAME WHICH IS ELECTRICALLY COMMON WITH ELECTRODE DRIVE ROLL AND DRIVEN ELECTRODE.

N.L. REMOVE JUMPER PLUG TO INSTALL OPTIONAL KIT. IF KIT IS REMOVED, REPLACE JUMPER PLUG.

N.M. NOT PRESENT ON EARLIER VOLTAGE P.C. BOARDS.

N.N. BLUE JUMPER LEAD NOT PRESENT ON EARLIER VOLTAGE P.C. BOARDS. THE JUMPER IS TO BE CONNECTED TO THE

BLUE

WHITE

RED

582

STOP

S6

581A

682

ELECTRODE LEAD BOLTED

142T

95S
57F

TIMER BOARD

(START TIME USE)

655

500

I

O

515

12

4

14

13

9

6

7

1

8

10

11

3

5

2

15

500

510P

515

520

635

632

584S

583S

584C

583C

588

563

564

564A

START RECEPT.

*

10

5

6

12

14

15

11

8

9

7

1

13

2

4

3

520

515

510P

500

583S

584S

588

588A

635

632

655

JUMPER PLUGS

*

10

5

6

12

14

15

11

8

9

7

1

13

2

4

3

520

515

510P

500

588

588A

635

632

655

584C

583C

CRATER RECEPT.

OPTIONAL PROCEDURE MODULE

USED FOR START CONTROL

5

4

3

2

1

6

581A

581

565

566

561

560

*

N.B.

N.C.

5

6

4

3

2

1

1

500

655

515

I

O

*

5
6
4
3
2
1

500
655
515

I

O

WELD TIME

RECEPT.

TIMER BOARD

655

500

I

O

515

OPTION BOARD

5

6

4

3

2

1

655

500

I

O

515

TIMER

RECEPT.

OPTIONAL PROCEDURE MODULE

USED FOR CRATER CONTROL

(CRATER TIME USE)

TIMER BOARD

(BURNBACK TIME)

500

655

515

I

O

START

S5

500

581A

581A

516

514

512

511

510P

601

602

517

519

655

500

I

O

515

WELD TIMER BOARD

(OPTIONAL)

N.A.

SET-ACTUAL

S7

PROCEDURE BOARD

*

BURNBACK
RECEPT.

531B

532

592

(COMPONENT SIDE OF P.C. BOARD)

SPEEDMETER NA-5 HEAD DRIVE ROLL WIRE SIZE RATED SPEED

562S

562S

562C

562C

142

95

57

1

2

3

4

1

2

3

4

5

6

1

2

3

4

5

6

7

8

9

1

2

3

4

5

6

7

8

9

10

11

12

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

J29

N.H. 531-87 115 VAC (SWITCHED) 1/2 AMP.

PIN "B" WHEN SHIPPED, FOR USE TYPICALLY WITH DC-[ ]TYPE POWER SOURCES. REFER TO CONNECTION
DIAGRAM FOR ALTERNATE CONNECTIONS, AND JUMPER CONNECTIONS FOR R3S, SAM AND SAF OR SA
POWER SOURCES WITH K224. EARLIER VOLTAGE BOARDS DO NOT CONTAIN PIN "D".

1/8 AMP FUSE

OPTIONAL PULSE POWER

TRAVEL RECEPT.

J5

1

562

583

655

515

500

584

588

588A

632

635

520

510P

9

10

8

3

2

6

4

12

5

11

*

7

P29 (C)

J29 (C)

J28 (C)

(CRATER FILL USE)

OPTION BOARD

5

6

4

3

2

1

655

500

I

O

515

TIMER

RECEPT.

1

562

583

655

515

500

584

588

588A

632

635

520

510P

9

10

8

3

2

6

4

12

5

11

*

7

(START USE)

J28 (S)

J29 (S)

P29 (S)

P28 (S)

J28

P28 (C)

CABLE

TO

532

87

610

532

585

589

FLUX RELAY MODULE

CR1

3

1

4

2

610

CR2

3

1

4

2

RELAY MODULE

RELAY MODULE

N.P.

532

TRAVEL

CONTACTOR

4

2

625

682

CR3

3

1

4

2

610

N.P.

N.P.

N.P. EARLIER RELAYS HAD SAME TERMINAL NUMBERS BUT IN A DIFFERENT ORIENTATION.

METHODS OF TRAVEL

START/STOP WITH SWITCHES

LEAD #691 to P6
LEAD #692 to P5

LEAD #691 to P6
LEAD #692 to P7

STOP WITH STOP SWITCH

LEAD #691 to P5
LEAD #692 to P7

START WITH START SWITCH
STOP AFTER CRATER TIME

LEAD #691 to P6
LEAD #692 to P9

FOR EARLIER LOGIC P.C.
BOARDS WITH JUMPERS

CONNECT

CONNECT

SWITCH #1

1

2

3

4

SWITCH #2

1

2

3

4

SWITCH #1

1

2

3

4

SWITCH #2

1

2

3

4

FOR LOGIC P.C. BOARDS WITH

CONNECT

CONNECT

SWITCH #1

1

2

3

4

SWITCH #2

1

2

3

4

SWITCH #1

1

2

3

4

SWITCH #2

1

2

3

4

FOR EARLIER LOGIC P.C.
BOARDS WITH JUMPERS

YES

CONNECT
LEAD #694 TO P10

NO

CONNECT
LEAD #694 TO P8

CRATER BOARD INSTALLED?

SWITCH #1

1

2

3

4

SWITCH #2

1

2

3

4

SWITCH #1

1

2

3

4

SWITCH #2

1

2

3

4

FOR LOGIC P.C. BOARDS WITH
DIP SWITCHES

DIP SWITCHES

FOR EARLIER LOGIC P.C.
BOARDS WITH JUMPERS

SWITCH #1

1

2

3

4

SWITCH #2

1

2

3

4

SWITCH #1

1

2

3

4

SWITCH #2

1

2

3

4

FOR LOGIC P.C. BOARDS WITH
DIP SWITCHES

1

2

3

4

1

2

3

4

METHODS OF BURNBACK

CONNECT
LEAD #690 TO P4
LEAD #693 TO P3

CONNECT
LEAD #690 TO P4
LEAD #693 TO P1

CONNECT
LEAD #690 TO P2
LEAD #693 TO P1

1

2

3

4

SAMPLE SWITCH

SWITCH POSITION 1 IS UP
SWITCH POSITION 2 IS DOWN
SWITCH POSITIONS 3 AND 4 ARE NOT APPLICABLE

NA-5 SHIPPED CONNECTED FOR INDICATED METHODS OF TRAVEL & BURNBACK.

START WITH START SWITCH

LEAD #691 to P6
LEAD #692 to P8

CONNECT

SWITCH #1

1

2

3

4

SWITCH #2

1

2

3

4

START/STOP WITH WELD CURRENT

START WITH WELD CURRENT

(OPTIONAL PROCEDURE MODULE
INSTALLED IN CRATER RECEPTACLE)

(OPTIONAL PROCEDURE MODULE
INSTALLED IN CRATER RECEPTACLE)

STOP AFTER BURN-BACK TIME

N.F. LOGIC BOARD DIP SWITCHES OR JUMPERS TO BE SET TO SUIT DESIRED APPLICATIONS PER CHARTS BELOW:

WIRE FEED STOP WITH
CONTACTOR DELAY

INCH UP WITH CONTACTOR DELAY

INCH UP WITH NO CONTACTOR
DELAY

USE OF OPTIONAL CRATER MODULE

N.R.

N.R.

N.R.

N.R. POTENTIOMETERS AND SWITCHES MOUNTED ON P.C. BOARD ARE CONNECTED TO FRAME, FOR ESD.

(NOT PRESENT ON EARLIER BOARDS)

G-2

NOTE: This diagram is for reference only. It may not be accurate for all machines covered by this manual.

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

Advertising