Troubleshooting & repair, Caution – Lincoln Electric NA-5S User Manual

Page 69

Advertising
background image

F-16

TROUBLESHOOTING & REPAIR

F-16

NA-5

Observe all Safety Guidelines detailed throughout this manual

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact the Lincoln Electric
Service Department for technical troubleshooting assistance before you proceed. Call 216-383-2531 or 1-800-833-9353.

CAUTION

MODE FUNCTION PROBLEMS

PROBLEMS

(SYMPTOMS)

POSSIBLE AREAS OF

MISADJUSTMENTS(S)

RECOMMENDED

COURSE OF ACTION

When welding the start timer does
not time out. The unit stays in the
start mode.

The crater light does not light. The
crater controls (voltage and wire
feed speed) may or may not func-
tion. The NA-5 is at idle with the
selector switch in the ”Crater” pos-
tion.

The crater light is ON but the crater
controls (voltage and wire feed
speed) do not function. The NA-5 is
at idle with the selector switch in the
“Crater” position.

1. When the weld is stopped check

to see if the crater (if used) or
burnback timer is functioning
properly. If the crater and or burn-
back timer IS functioning properly
the start timer may be faulty.

2. If the start, crater and burnback

timers are not working properly
the procedure board may be
faulty.

1. Make sure the crater option

boards are installed correctly.

2. The procedure board may be

faulty. Replace.

1. If no other lights are lit the crater

option board may be faulty.
Replace.

2. If the strike light is also lit (along

with the crater light) the logic
board may be faulty.

3. If the weld and or start lights are

also lit (along with the crater light)
the procedure board may be
faulty.

1. Check the lead harness between

the start option boards and the
procedure board for loose or
faulty connections. See wiring
diagram.

1. Check the lead harness between

the crater option boards and the
procedure board for loose or
faulty connections. See wiring
diagram.

1. Check the lead harness between

the crater option boards and the
procedure board for loose or faulty
connections. See wiring diagram.

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

Advertising