TABLE B.2 – STOPPING SEQUENCE SETTINGS.

When “Stop” Button

is Pressed

Older Models

Newer Models*

Feed motor stops and

Lead #693 to Pin 3

electrode burns back with

Lead #690 to Pin 4

contactor delay (standard)

Feed motor inches up and

Lead #693 to Pin 1

electrode burns back with

Lead #690 to Pin 4

contactor delay

Feed motor inches up and

Lead #693 to Pin 1

contactor opens

Lead #690 to Pin 2

(no burnback)

*NOTE:

VOLTAGE CONTROL
RESPONSE

The NA-5 is provided with selectable voltage
control response. Proper setting depends on
the power source and process being used.
Refer to the appropriate power source
connection diagram for the proper
connection of the jumpers located on the
NA-5 Voltage P.C. Board, shown in Figure
B.3.

To change the voltage control response:

1. Turn off all input power to the NA-5

control.

2. Open the control box.

3. Locate the Voltage P.C. Board

mounted on the right side of the box.
Position the jumper plugs on the
Voltage P.C. Board per the
appropriate power source connection
diagram.

1

2

3

4

Switch #2

1

2

3

4

Switch #2

1

2

3

4

Switch #2

OPERATING INSTRUCTIONS

B-9

B-9

NA-5

Indicates switch in up position

Indicates switch in down position

Indicates switch position does not matter

NA-5

VOLTAGE

A

D

B

RED

JUMPER

PLUG

WHITE

JUMPER

PLUG

FIGURE B.3 – VOLTAGE CONTROL

RESPONSE JUMPER PLUG

LOCATIONS.

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC