ACCESSORIES

C-5

C-5

NA-5

K334 START AND CRATER
CONTROLS

Easily installed procedure and timer boards
to permit adjustment of wire speed and
voltage. Can be installed to function at
either the start of the weld or at the end for
crater filling. Installation, operating, and
maintenance instructions are shipped with
each kit and can be ordered as Sec. T2.5.13
K334.

K336 REMOTE INTERFACE
MODULE

Permits connection of customer-furnished
remote start-stop and inch momentary
contact closure or momentary 24 volt
signals. Also used when a single remote
signal is desired to start or stop multiple
heads. This module replaces the earlier
K336 Remote Pushbutton Interface Module.
Installation and application instructions are
shipped with each kit and can be ordered as
Sec. T2.5.11 K336.

K337 WELD TIMER MODULE

Permits setting of weld time for an adjustable
period. Eliminates need to press the “Stop”
button. Instructions are included in the kit.

K349 MULTI-PROCEDURE KIT

The K349 Multi-Procedure Kit provides three
additional weld mode procedure settings of
wire feed speed and voltage, allowing the
choice of four NA-5 weld mode procedures.
Installation, operating, and maintenance
instructions are shipped with each kit, are
contained in the IM305 manual, and can be
ordered as Sec. T2.5.19 K349.

S22022 OR S22182 CURRENT
RELAY MODULES

The current relay is useful to fixture builders
and others who need a signal indicating that
welding current is flowing. Installation,
operating, and maintenance instructions are
shipped with each kit. The S22022 relay
module is suitable for dry circuit applications
and it is rated at 2 Amps, 115 VAC or 28
VDC. This relay has both normally open and
normally closed contacts. The S22182 relay
module is suitable for applications requiring
at least 10 mA current and it is rated at 3
Amps, 115 VAC or 28 VDC. This relay only
has normally open contacts.

SPEED-FEED DRUM

These drums must be set on a turntable
which permits them to freely turn in a
clockwise direction. Installation, operating,
and maintenance instructions are contained
in the IM305 manual and can be ordered as
Sec. T2.5.7-A.

SPEED-FEED REEL

These reels require dereeling equipment
that permits the reel to rotate freely as the
electrode is used. Installation, operating,
and maintenance instructions are contained
in the IM305 manual and can be ordered as
Sec. T2.5.7-B.