Welding head, Ground fault fuse protection, Wire drive gear box – Lincoln Electric NA-5S User Manual

Page 44: Maintenance

Advertising
background image

MAINTENANCE

D-3

D-3

NA-5

The 1/8 amp fast-blow fuse, shown in Figure
D.3, on a voltage PC board built since 1983,
protects the NA-5 circuitry from damage
which may result from a ground or case
faulted control lead. If the fuse blows, the
NA-5 voltage sensing lead circuit will be
opened (Refer to

Automatic Shutdown in

Section B, Operating Procedures) and the
Troubleshooting Guide.

FIGURE D.3 – VOLTAGE BOARD FUSE

LOCATION.

GROUND FAULT FUSE
PROTECTION

A 1/8 amp fast-blow fuse, shown in Figure
D.3, is located on the voltage PC board.
This fuse will protect the NA-5 circuitry from
damage resulting from a ground or case
faulted control lead when the arc voltage
potential exists between ground and the

NA-5 circuit common (#510). Such a
condition typically exists when the NA-5
polarity connections are set for electrode
negative.

WELDING HEAD

WIRE DRIVE GEAR BOX

Once a year, recoat all gear teeth with a
non-fluid molydisulfide type grease such as
Non-Fluid Oil Corporation’s A-29 Special/MS
Lubricant. For access to the gears in the first
chamber, remove the adapter plate and
motor assembly as shown in Figure D.4.

FIGURE D.4 – WIRE DRIVE MOTOR

GEAR BOX.

To lubricate the gears in the second
chamber, remove one of the pipe plugs and
feed grease until it comes in contact with the
bevel gear teeth. Then, rotate the output
shaft by hand until all teeth are lubricated.

1/8 AMP

FAST-BLOW

FUSE

NA-5

VOLTAGE

HEX HEAD

SCREW

ADAPTER

PLATE AND

MOTOR

ASSEMBLY

FIRST

CHAMBER

WIRE DRIVE

GEARBOX

SECOND

CHAMBER

SLOT HEAD

SCREW

PIPE
PLUG

DRIVE MOTOR

BRUSH ACCESS

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC