Figure a.8 — connection of na-5 (all) to a dc-600, A.8 to a.14), Installation – Lincoln Electric NA-5S User Manual

Page 16

Advertising
background image

INSTALLATION

A-9

A-9

NA-5

FIGURE A.8 – CONNECTION OF NA-5 (ALL) TO A DC-600.

N.A. ON EARLIER DC-600'S, #67 TERMINAL WAS ALSO ON THE TERMINAL STRIP.
N.B. WELDING CABLES MUST BE OF PROPER CAPACITY FOR THE CURRENT AND DUTY CYCLE OF IMMEDIATE AND FUTURE APPLICATIONS.
N.C. EXTEND LEAD #21 USING #14 OR LARGER INSULATED WIRE PHYSICALLY SUITABLE FOR THE INSTALLATION. AN S-16586 - [ ] REMOTE VOLTAGE SENSING WORK

LEAD IS AVAILABLE FOR THIS PURPOSE. CONNECT IT DIRECTLY TO THE WORK PIECE KEEPING IT SEPARATE FROM THE WELDING WORK CABLE CONNECTION
TO THE WORK PIECE. FOR CONVENIENCE, THIS EXTENDED #21 LEAD SHOULD BE TAPED ALONG THE WELDING WORK CABLE.

N.D. TAPE UP BOLTED CONNECTION.
N.E. CONNECT THE NA-5 CONTROL CABLE GROUNDING LEAD TO THE FRAME TERMINAL MARKED NEAR THE POWER SOURCE TERMINAL STRIP. THE POWER

SOURCE MUST BE PROPERLY GROUNDED.

N.F. IF USING AN OLDER K-215 CONTROL CABLE: CONNECT LEAD #75 TO #75 ON TERMINAL STRIP, CONNECT LEAD #76 TO #76 ON TERMINAL STRIP, CONNECT

LEAD #77 TO #77 ON TERMINAL STRIP.

N.G. THE JUMPERS ON THE NA-5 VOLTAGE BOARD MUST BE CONNECTED AS FOLLOWS: CONNECT RED JUMPER TO PIN "S". CONNECT WHITE JUMPER TO PIN "B".
N.H. CONNECT A JUMPER FROM "N" TO "P". THERE IS NO NPS TERMINAL STRIP ON DC-600 CODES ABOVE 8200.
N.J. FOR PROPER NA-5 OPERATION, THE ELECTRODE CABLES MUST BE SNUGGED UNDER THE CLAMP BAR ON THE LEFT SIDE OF THE NA-5 CONTROL BOX.

NOTE:

DIAGRAM SHOWS ELECTRODE CONNECTED POSITIVE.

TO CHANGE POLARITY, TURN POWER OFF, REVERSE THE

ELECTRODE AND WORK CABLES AT THE POWER SOURCE

AND POSITON THE SWITCH ON POWER SOURCE TO PROPER
POLARITY. REFER TO NA-5 OPERATING MANUAL FOR REQUIRED
NA-5 CONTROL BOX POLARITY CONNECTIONS.

ALL CODES:
TURN OFF INPUT POWER
ADJUST THE POWER SOURCE: DC-600:
1. CONNECT ELECTRODE CABLES TO TERMINAL OF DESIRED POLARITY.
2. SET TOGGLE SWITCH TO SAME POLARITY AS THE ELECTRODE CABLE

CONNECTION.

3. SET TOGGLE SWITCH TO "REMOTE".
4. SET MODE SWITCH TO THE DESIRED POSITION FOR THE PROCESS TO BE USED.

DC-600 CODES 8000-8045:
FOR SUB ARC:
1. SET MODE SWITCH TO CV SUB ARC.
2. WHITE LEAD ON CONTROL PC BOARD IS CONNECTED TO PIN "M" AND BLUE

LEAD IS CONNECTED TO "W".

FOR ALL OPEN ARC PROCESSES EXCEPT NR-302 AND NR-203 ELECTRODES:
1. SET MODE SWITCH TO CV INNERSHIELD.
2. WHITE LEAD ON CONTROL PC BOARD IS CONNECTED TO PIN "M" AND BLUE

LEAD IS CONNECTED TO "W".

FOR NR-203 AND NR-302 ELECTRODES:
1. SET MODE SWITCH TO CV INNERSHIELD.
2. WHITE LEAD ON CONTROL PC BOARD IS CONNECTED TO PIN "I"

AND BLUE LEAD IS CONNECTED TO "S".

DC-600 CODES 8046-8200:
FOR SUB ARC:
1. SET MODE SWITCH TO CV SUB ARC.
2. WHITE LEAD ON CONTROL PC BOARD IS CONNECTED TO PIN "M".

FOR ALL OPEN ARC PROCESSES EXCEPT MR-203 ELECTRODES:
1. SET MODE SWITCH TO CV INNERSHIELD.
2. WHITE LEAD ON CONTROL PC BOARD IS CONNECTED TO PIN "M".

FOR NR-203 ELECTRODES:
1. SET MODE SWITCH TO CV INNERSHIELD.
2. WHITE LEAD ON CONTROL PC BOARD IS CONNECTED TO PIN "I".

DC-600 CODES ABOVE 8200:
FOR SUB ARC:
1. SET MODE SWITCH TO CV SUB ARC.
FOR ALL OPEN ARC PROCESSES:
2. SET MODE SWITCH TO CV INNERSHIELD.

FOR OPTIMUM PERFORMANCE WITH NA-5, DC-600'S WITH CODES 8288 AND
ABOVE ARE PREFERRED. FOR ADDITIONAL INSTALLATION INSTRUCTIONS,
SEE NA-5 OPERATING MANUAL.

P

A

B

P

B

.

A

.

TO NA-5 INPUT

CABLE PLUG

CONNECT TO CABLES FROM NA-5

WIRE CONTACT ASSEMBLY

CONNECT

TO WORK

CLEVELAND, OHIO U.S.A.

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

Advertising
This manual is related to the following products: