G-6

ELECTRICAL DIAGRAMS

NA-5

POWER PC BOARD (L6252-2 & above) SCHEMATIC

CR1

OFF

TRAVEL

AUTO

HAND

S1B

CR7

626

666

CR6

S2

FOR THE NA-5R ONLY:

BURNBACK KIT IS CONNECTED TO 631 AND 532.

631

AND CR2 ARE REMOVED ON THE NA-5R.

MOTOR ARMATURE

WIRE FEED

18

115 VAC

531B

532

WIRE FEED

3000

.0047

3000

.0047

BLK

531B

RED

MOTOR FIELD

WHT

500

P1

J3

6

P1

J3

1

P1

J3

5

-10V

500

500

POWER SUPPLY

RELAY

500

500

J2

4

25

2

GND

SHOWN WITH JUMPER
PLUG INSTALLED

NA-5R OPTIONAL BURNBACK

4

404

1

2

3

6

5

4

402

532

RECEPTACLE WHICH IS DRAWN BELOW.THE

CR3 IS SHOWN IN THE OPTIONAL BURNBACK KIT

L

TRAVEL

RECEPTACLE

532

THE TRAVEL RECEPTACLE,THE TRAVEL SWITCH,

4

2

CR3

GND

32

KIT RECEPTACLE

CR3

CONTROL POWER AND
EMERGENCY STOP

S1A

31

115VAC

INPUT

8956

531

531

531

GND

3000

.0047

C22

16A
400V

D2

539

LED1D

16A
400V

D1

500

525

UNLESS OTHERWISE SPECIFIED)

(UNLESS OTHERWISE SPECIFIED)

UNLESS OTHERWISE SPECIFIED)

LABELS

C-

D-

R-

541

ELECTRICAL SYMBOLS PER E1537

M

BLUE

1/4W

.022/50V

GENERAL INFORMATION

(

DIODES =

RESISTORS = Ohms (

1A, 400V

MFD

CAPACITORS =

24

EQUIP.

22

POWER SUPPLY SOURCE POINT

EARTH GROUND CONNECTION

COMMON CONNECTION

FRAME CONNECTION

LAST NO. USED

VOLTAGE NET

540

NA-5,NA-5R

J1

4

0.5A

125V

F2

50
250V

C3

P1

J1

1

12W

40

R1

LED1C

133K

R2

627

133K

R18

LED1E

150V

45J

TP1

200V

.15

C2

1400V

.0047

C1

0.5A

125V

F1

0.2mH
PT1

1

2

SHT.

J2

5

L

SUP'S'D'G.

SUBJECT

NO.

P1

J3

3

0.2mH

PT2

1

2

8956

15

100V

.047

C5

2N6398

SCR1

200V

.15

C4

TYPE

SUPPLY

631

0.2mH

PT3

1

2

600V

.02

C21

100

R3

2N6403

SCR3

2N6403

SCR4

BLACK

16A

400V

2W

10K

R5

FEED FORWARD

D3

100V

.047

C19

6.81K

R10

13.7K

R20

4.7
35V

C7

2N6027

QU1

2

3

1

P1

J1

3

4.75K

R9

C24

332

R21

P1

J1

6

100

R6

0.2mH

PT1

5

6

100V

.047

C6

100

R4

J2

1

0.2mH
PT1

3

4

2N6398

SCR2

LED1F

133K

R16

D9

1N4007

D12

1N4007

D15

GND

IN

OUT

X2

B3

B4

D7

D6

B5

1N4007

D13

1N4007

D14

610

150V
45J

TP3

J2

6

600V

.02

C18

LED1B

LED1A

D10

500
50V

C15

D11

4.7
35V

C16

500
50V

C14

500

610

ARMATURE SUPPLY

B1

D4

133K

R17

18
15V

C17

D5

3.32K

R15

(HS)

IN

7815

OUT

GND

X1

1W

5.1V

DZ1

100V

.22

C13

B2

4.75K

R14

D8

BRN

24

VAC

T2B

532

10 VAC

531B

T2A

YLW

BLK

602

601

YLW

BLK

BRN

115 VAC

532

BLK

T1B

METER

VAC

CANADA

ORG

115

ORG

RED

AUSTRALIA

POWER SUPPLY

INTERFACE OPTION

FRANCE

87

FLUX OR WATER

R1

SOLENOID RECEPTACLE

2 OHMS

50 WATTS

531A

CB1

531A

631

.0047

3000

VAC

CR2

T1A

SUPPLY

J2

3

J2

2

150V

45J

TP2

VAC

WHT

18

RED

FIELD SUPPLY

40V

600mA

Q9

0.2mH

PT3

3

4

40V

600mA

Q3

1.50K

R19

C20

681

R11

P1

J3

8

P1

J3

4

10K

R7

100V

.047

C8

40V

600mA

Q1

P1

J3

9

P1

J3

2

47.5K

R8

C12

0.2mH

PT2

3

4

C9

33.2K

R22

C10

C11

40V

600mA

Q2

500

510

525

NONE

SCALE

CHK.

DATE

Ch'ge.Sht.No.

DR.

47.5K

R12

THE LINCOLN ELECTRIC CO.

CLEVELAND, OHIO U.S.A.

K.K.

ON ALL ANGLES IS + .5 OF A DEGREE

ON 3 PLACE DECIMALS IS + .OO2

ON HOLES SIZES PER E-2056

UNLESS OTHERWISE SPECIFIED TOLERANCE

ON 2 PLACE DECIMALS IS + .O2

WITH PUBLISHED STANDARDS

MATERIAL TOLERANCE ("t") TO AGREE

N.A. SINCE COMPONENTS OR CIRCUITRY ON A PRINTED CIRCUIT BOARD MAY CHANGE

CIRCUIT

ANALOG

REFERENCE

POWER SUPPLY

FIELD DIRECTION

NOT SHOW THE EXACT COMPONENTS OR CIRCUITRY OF CONTROLS HAVING A COMMON CODE

WITHOUT AFFECTING THE INTERCHANGEABILITY OF A COMPLETE BOARD, THIS DIAGRAM MAY

NUMBER.

NOTES :

P1

J3

7

587

510

510

ZERO VOLT

ANALOG

525

+15V

525

5/12/92

POWER P.C. BOARD SCHEMATIC

G-6

NOTE: Lincoln Electric assumes no responsibility for liablilities resulting from board level troubleshooting. PC Board repairs will invalidate your factory warranty. Individual Printed Circuit Board Components are not avail-

able from Lincoln Electric. This information is provided for reference only. Lincoln Electric discourages board level troubleshooting and repair since it may compromise the quality of the design and may result in
danger to the Machine Operator or Technician. Improper PC board repairs could result in damage to the machine.

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

Advertising
This manual is related to the following products: