TROUBLESHOOTING & REPAIR

F-15

NA-5

Observe all Safety Guidelines detailed throughout this manual

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact the Lincoln Electric
Service Department for technical troubleshooting assistance before you proceed. Call 216-383-2531 or 1-800-833-9353.

CAUTION

MODE FUNCTION PROBLEMS

PROBLEMS

(SYMPTOMS)

POSSIBLE AREAS OF

MISADJUSTMENTS(S)

RECOMMENDED

COURSE OF ACTION

When the start button is pressed and
the unit is welding, the start mode is
skipped.

1. Make sure the start option is in-

stalled properly in the NA-5.

2. Make sure the start timer is set

for a time greater than zero sec-
onds.

3. If the weld light goes ON as soon

as (but not before) the arc is
struck and the start timer is set
for a time greater than zero sec-
onds, the start timer board may
be faulty.

4. If the weld light goes ON before

the arc is struck replace the start
option board with the jumper
plug. If the weld light continues
to go ON before the arc is struck
the logic board may be faulty.
Replace.

5. With the jumper plug installed: If

the weld light does NOT go ON
until the arc is struck the start
option board may be faulty.

1. Check the lead harness between

the start option boards and the
procedure board for loose or
faulty connections. See wiring
diagram.