INSTALLATION

A-14

A-14

NA-5

FIGURE A.13 – CONNECTION OF NA-5 TO DC-1000 OR DC-1500.

THE DIAGRAM SHOWS ELECTRODE CONNECTED POSITIVE. TO CHANGE POLARITY, TURN POWER OFF, REVERSE THE ELECTRODE AND WORK LEADS AT THE
POWER SOURCE, POSITION THE POSITIVE-NEGATIVE SWITCH ON THE POWER SOURCE TO CORRESPOND TO THE POLARITY OF THE ELECTRODE CABLE CONNECTION.
REFER TO NA-5 OPERATING MANUAL FOR REQUIRED NA-5 CONTROL BOX POLARITY CONNECTIONS.

P

POWER SOURCE

CONTROL
CABLE

BOLT TO CABLES FROM
NA-5 WIRE CONTACT
ASSEMBLY

INPUT CABLE PLUG

N.A. WELDING CABLES MUST BE OF PROPER CAPACITY FOR THE CURRENT AND DUTY CYCLE OF IMMEDIATE AND FUTURE APPLICATIONS.
N.B. EXTEND LEAD 21 USING #14 OR LARGER INSULATED WIRE PHYSICALLY SUITABLE FOR THE INSTALLATION. AN S-16586-[ ] REMOTE VOLTAGE-SENSING WORK LEAD

IS AVAILABLE FOR THIS PURPOSE. CONNECT IT DIRECTLY TO THE WORK PIECE KEEPING IT SEPARATE FROM THE WELDING WORK CABLE CONNECTION TO
WORK PIECE. FOR CONVENIENCE, THIS EXTENDED #21 LEAD SHOULD BE TAPED ALONG THE WELDING WORK CABLE.

N.C. TAPE UP BOLTED CONNECTION.
N.D. CONNECT THE NA-5 CONTROL CABLE GROUND LEAD TO THE FRAME TERMINAL MARKED NEAR THE POWER SOURCE TERMINAL STRIP. THE POWER SOURCE

MUST BE PROPERLY GROUNDED.

N.E. IF USING AN OLDER AUTOMATIC CONTROL CABLE WITH LEADS 75, 76, 77; CONNECT LEAD 75 TO #75 ON TERMINAL STRIP, CONNECT LEAD #76 TO #74 ON TERMINAL

STRIP, CONNECT LEAD #77 TO #73 ON TERMINAL STRIP.

N.F. CONNECT THE JUMPERS ON THE NA-5 VOLTAGE BOARD AS FOLLOWS: CONNECT RED JUMPER TO PIN "S". CONNECT WHITE JUMPER TO PIN "B".
N.G. SET THE DC-1000 OR DC-1500 CONTROLS AS FOLLOWS: SET THE CONTROL SWITCH TO "OUTPUT CONTROL REMOTE".

FOR SUBMERGED ARC PROCESSES, SET THE MODE SWITCH TO "C.V. SUBMERGED ARC". FOR OPEN ARC PROCESSES, SET THE MODE
SWITCH TO "C.V. INNERSHIELD"

N.H. FOR PROPER OPERATION, THE ELECTRODE CABLE MUST BE SNUGGED UNDER THE CLAMP BAR ON THE LEFT SIDE OF THE NA-5 CONTROL BOX.
N.J. TERMINALS #73 AND #74 WERE NOT PRESENT ON DC-1500 MACHINES BELOW CODE 8294. THESE EARLIER CODE MACHINES ARE NOT SUITABLE FOR

USE WITH THE NA-5.

N.K. ALTERNATIVE 500 AMP POSITIVE TERMINAL CONNECTION PROVIDED ON DC-1000 MODELS ABOVE CODE 9500 ONLY.
N.L. ALTERNATE SUBMERGED ARC MODE AVAILABLE FOR IMPROVED ARC STABILITY IN HIGH CURRENT, LARGE PUDDLE, SLOW TRAVEL PROCEDURES BY MAKING

SPECIAL CONNECTIONS ON BOTH DC-1500 AND NA-5.
ON DC-1500 CONTROL BOARD (G-1530-2 AND SUPERSEDING) REMOVE RED AND BLUE JUMPERS FROM "FR" PINS AND RECONNECT TO CORRESPONDING "SR" PINS.
ON NA-5 VOLTAGE BOARD (G-1556-1 AND SUPERSEDING) WHITE JUMPER MUST BE CONNECTED TO PIN "D".
NA-5 PIN "D" CONNECTION MAY ALSO BE USED FOR SOME PROCEDURES ON DC-1500 WITHOUT CONTROL BOARD JUMPERS, DC-1500 WITH CONTROL BOARD
JUMPERS ON "FR" PINS OR DC-1000.

CONNECT TO WORK

CLEVELAND, OHIO U.S.A.