Troubleshooting & repair, Meter circuit accuracy test – Lincoln Electric NA-5S User Manual

Page 120

Advertising
background image

F-67

TROUBLESHOOTING & REPAIR

F-67

8. Test Voltmeter PC Board Accuracy

• Use a test meter with at least 3-

1/2 digits and +/- 0.5% accuracy.

• Connect the + probe to lead #517

and the - probe to lead #510C.
Do not disconnect plug.

Note: The coating will have to be
removed from the test points to ensure
accurate meter readings.

• With the NA-5 voltmeter reading

SET values of STRIKE voltage,
adjust the strike voltage control
until the NA-5 voltmeter matches
the settings in the table below.

• If the test meter does not match

the readings, the voltmeter PC
board may be faulty.

METER CIRCUIT ACCURACY TEST

(Continued)

NA-5

NA-5 SET VOLTS READING

TEST VOLTMETER READING

15.0VDC

1.50VDC +/- .04

30.0VDC

3.00VDC +/- .04

60.0VDC

6.00VDC +/- .06

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

Advertising
This manual is related to the following products: