Cr3 relay, Troubleshooting & repair, Voltmeter accuracy test – Lincoln Electric NA-5S User Manual

Page 112

Advertising
background image

F-59

TROUBLESHOOTING & REPAIR

F-59

4. Remove the jumper wire from leads

#2 and #4.

5. Remove the test voltmeter and,

while welding, compare the SET
volts and ACTUAL volts meter read-
ings. Depending upon the arc volt-
age characteristics of the process
being welded, the ACTUAL reading
may vary somewhat about an aver-
age value. The average ACTUAL
reading should match the SET read-
ing within +/- 0.5 VDC. If not, refer
to the

Meter Circuit Accuracy Test.

6. If no further tests are required,

remove all test equipment and close
and secure the access door.

VOLTMETER ACCURACY TEST

(Continued)

NA-5

FIGURE F.8 CR3 RELAY

CR3 RELAY