OPERATING INSTRUCTIONS

B-7

B-7

NA-5

Travel Starts

Travel Stops

Older Models

Newer Models*

With “Start”

With “Stop”

Lead #691 to Pin 6

Button

Button

Lead #692 to Pin 5

With Arc Striking With Arc Stopping

Lead #691 to Pin 6
Lead #692 to Pin 7

With Arc Striking With Stop Button

Lead #691 to Pin 5
Lead #692 to Pin 7

With “Start”

With End Crater

Lead #691 to Pin 6

Button

Fill Time (With

Lead #692 to Pin 9

optional procedure
module installed in
crater receptacle

1

)

With “Start”

After Burnback

Lead #691 to Pin 6

Button

Time (with

Lead #692 to Pin 8

optional procedure
module installed
in crater
receptacle

1

)

1

2

3

4

1

2

3

4

Switch #1

Switch #2

1

2

3

4

1

2

3

4

Switch #1

Switch #2

1

2

3

4

1

2

3

4

Switch #1

Switch #2

1

2

3

4

1

2

3

4

Switch #1

Switch #2

TABLE B.1 – TRAVEL SEQUENCE LEAD AND SWITCH POSITIONS.

1

2

3

4

1

2

3

4

Switch #1

Switch #2

*NOTE:

Indicates switch in up position

Indicates switch in down position

Indicates switch position does not matter

1If the optional procedure module is installed in the crater receptacle,

DIP switch position 1 on switch #2 should be in the UP position as
shown. Additionally, remove 583C to 584C jumper plug from the pro
cedure board. If the procedure module is not installed, the switch
should be in the down position and the 583C to 584C jumper plug
should be reinstalled on the procedure board.