F-41

TROUBLESHOOTING & REPAIR

F-41

DC POWER SUPPLY TEST (continued)

NA-5

CHECK POINT

TEST

CONNECTOR

LEAD NO.

NORMAL

LOCATION

DESCRIPTION

PLUG PIN NO.

ACCEPTABLE

VOLTAGE

READING

PROCEDURE

CHECK +15VDC

PLUG J19

515 +

PC BOARD

SUPPLY FROM

PIN 5 +

J19 CONNECTOR

LOGIC BOARD

14.0 - 16.0 VDC

PLUG

TO

PLUG J19

500 -

PROCEDURE BOARD

PIN 15 -

VOLTMETER

CHECK +5VDC

TEST POINT

1.

TP5 +

BOARD SUPPLY

TP5

+

PRODUCED

4.75 - 5.25 VDC

ON THE

VOLTMETER TEST

POINT

1.

LEAD 510P -

BOARD 510P

-

SPEEDMETER

CHECK +5VDC

TEST POINT

1.

TP5 +

BOARD

SUPPLY

TP5 +

4.75 - 5.25 VDC

PRODUCED

ON THE

TEST POINT

1.

LEAD 510P -

SPEEDMETER 510P

-

BOARD

TABLE F.1 DC POWER SUPPLY CHECKS (continued)

500 -

515 +

1.

Scrape encapsulation from test points.

Return to Section TOC