Starting and stopping sequences, Means of arc striking, Starting and stopping – Lincoln Electric NA-5S User Manual

Page 28: Sequences, Sequence. see the, Starting and, Stopping sequences, Controls”. see the, Operating instructions

Advertising
background image

OPERATING INSTRUCTIONS

B-5

B-5

NA-5

11. Set the travel speed as specified by

the procedures. With the wire feeder
travel switch set to “Hand Travel”, the
travel runs without welding, permitting
accurate measurement of travel
speed. When using a Lincoln travel
carriage, adjust the speed with the
rheostat and the direction with the
toggle switch on the carriage control
panel.

12. Connect the work lead to the work or

a suitable piece of scrap. Clip the
end of the electrode to a sharp point.

13. Preset the “Start” (if used), “Weld”,

and “Crater” (if used) controls to the
wire speed and voltage specified in
the procedure.

14. Make several test welds, readjusting

the controls in the following order:

a. Set the “Arc Striking”, “Inch Wire

Speed”, and “Volts” controls for
optimum arc striking. The
optimum strike control settings for
most processes will be typically 4
to 5 volts higher than the weld
mode voltage setting and 40% to
50% of the weld mode wire feed
speed setting (possibly lower if
cold starting is used).

b. If striking is still not satisfactory,

refer to the section on

Setting

Travel Starting and Stopping or
IM305 Sec. T3.5.2 for information
on wire feed motor acceleration.

c. If installed, adjust the “Start

Controls” to set the welding
procedures for the time set on the
timer to provide the bead size,
penetration, or other factor as
needed for the application.

d. If installed, adjust the “Crater

Controls” to set the welding
procedures for the set time after
the “Stop” button is pressed to
provide the bead size or fill the
crater as needed for the
application.

e. Set the “Burnback

Time” to

provide the stopping char-
acteristics needed.

STARTING AND STOPPING
SEQUENCES

MEANS OF ARC STRIKING

The NA-5 Codes utilize “hot start” arc
striking which operates as follows
:

1. With the electrode not touching the

work, press the “Start” button.

2. The electrically “hot” electrode

inches down as set by the “Inch Wire
Speed” control.

3. When the electrode makes contact

with the work, the arc strikes and the
circuit automatically switches from
“Strike” settings to “Weld” (or “Start”,
if used) settings.

NA-5 models above Code 8300 offer both
“hot start” arc striking, as described
above, or “Cold Start” arc striking which
operates as follows
:

1. Press the “Inch Down” button until the

tip of the electrode touches the work,
automatically stops, and the flux (if
used) is automatically dispensed.

NOTE: If inch speed is set too high, the
electrode may stop with too much force on
its tip, resulting in possible poor starting.

2. The arc establishes when the “Start”

button is pressed, and the circuit
automatically switches to “Weld” (or
“Start”, is used) settings. Should the
arc not start immediately, the wire will
retract slightly until the arc is
established and then feed down in the
normal manner.

Use either the standard “on-the-fly” travel
starting or rewire the controls for “standstill”
travel starting as described in the

Setting

Travel Starting and Stopping section.

Optional “Start Controls”

Recommended for applications where
penetration, bead size, and other
characteristics must be carefully controlled
at the start.

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

Advertising