Troubleshooting & repair – Lincoln Electric NA-5S User Manual

Page 128

Advertising
background image

F-75

TROUBLESHOOTING & REPAIR

F-75

DIGITAL METER REMOVAL
PROCEDURE

1. Using the phillips head screwdriver

remove the four screws from the
meter bezel. See Figure F.12

2. Carefully remove the bezel assem-

bly.

3. Carefully remove the meter shield

assembly.

4. Using the 5/16" nutdriver, remove

the two nuts, screws and lockwash-
ers holding the digital meter to the
cover assembly.

5. Carefully remove the digital meter.

DIGITAL METER AND METER PC BOARD REMOVAL AND REPLACEMENT

NA-5

FIGURE F.12 METER BEZEL AND SCREW LOCATIONS

METER BEZEL

METER SHIELD

DIGITAL

METER

MOUNTING

INSULATOR

METER SHIELD

ASSEMBLY

Return to Section TOC