Troubleshooting & repair, Caution – Lincoln Electric NA-5S User Manual

Page 58

Advertising
background image

F-5

TROUBLESHOOTING & REPAIR

F-5

NA-5

Observe all Safety Guidelines detailed throughout this manual

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact the Lincoln Electric
Service Department for technical troubleshooting assistance before you proceed. Call 216-383-2531 or 1-800-833-9353.

CAUTION

WIRE FEEDING PROBLEMS

PROBLEMS

(SYMPTOMS)

POSSIBLE AREAS OF

MISADJUSTMENTS(S)

RECOMMENDED

COURSE OF ACTION

The wire does not feed. Pressing
any of the switches (buttons) will
NOT feed the wire. The motor does
NOT run.

1. Make sure input power switch is

ON.

2. Check the circuit breaker (CB1).

Reset if tripped.

3. Make sure 115VAC is being

applied to the control box through
the control cable receptacle.
Leads #31 and #32.

4. Check the two fuses on the

power board. Replace if blown. If
fuse F101 immediately fails when
replaced contact your local
Lincoln Authorized Field Service
Facility.

5. Make sure the motor cable is con-

nected to the motor receptacle on
the NA-5 control box.

1. Check the lights (LEDS) locate on

the PC boards. Some should be
lit. See

Table F.1. If none of the

lights are lit perform the

T1 and

T2 Transformer Test.

2. If the appropriate lights are lit

(see Table F.1.) and the wire
does NOT feed perform the

Wire

Drive Motor Test.

3. If only some of the appropriate

lights on the power board are lit
the power board may be faulty.

4. If all of the appropriate lights are

lit, except light 1D on the power,
board, check resistor R1. Normal
resistance is 2 ohms. See wiring
diagram.

5. If fuse F101 immediately fails

when input power is applied,
unplug all of the PC boards
except the power board. If the
fuse still fails the power board
may be faulty. If the fuse does
not fail reconnect the PC boards
one at a time until the faulty
board is located. Also check and
inspect the wiring harness for
“short” or “grounds”. Reconnect
the PC boards in the following
order: control, voltage,logic,pro-
cedure,option,timer, remote inter-
face,speedmeter and voltmeter.

NOTE: Some of the above PC
boards are optional and may not
be used in all NA-5 control units.

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

Advertising