The na-5 repeatedly shutsdown while welding, Troubleshooting & repair, Caution – Lincoln Electric NA-5S User Manual

Page 81

Advertising
background image

F-28

TROUBLESHOOTING & REPAIR

F-28

NA-5

Observe all Safety Guidelines detailed throughout this manual

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact the Lincoln Electric
Service Department for technical troubleshooting assistance before you proceed. Call 216-383-2531 or 1-800-833-9353.

CAUTION

FUNCTION PROBLEMS

PROBLEMS

(SYMPTOMS)

POSSIBLE AREAS OF

MISADJUSTMENTS(S)

RECOMMENDED

COURSE OF ACTION

The NA-5 repeatedly shutsdown
while welding.

1. Make sure the power source

polarity switch is set for the cor-
rect electrode polarity.

2. Make sure the #67 and #21 leads

are connected to the TS1 termi-
nal strip for the correct electrode
polarity. See wiring diagram.

3. Make certain the voltage control

switch on the Lincoln CV power
source is set in the “Remote”
position.

4. Make sure the #21 lead has con-

tinuity (zero ohms) to the work
piece.

5. Make sure the #67 lead has con-

tinuity (zero ohms) to the wire
feed head assembly.

6. Check the 1/8 amp fuse on the

NA-5 voltage board. Replace if
faulty.

7. The control cable may be faulty.

Check or replace.

8. Be sure the welding power

source is compatable with the
NA-5.

1. Perform the

Out of Voltage

Range Shutdown Test.

2. The voltage board may be faulty.