F-30

TROUBLESHOOTING & REPAIR

F-30

NA-5

Observe all Safety Guidelines detailed throughout this manual

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact the Lincoln Electric
Service Department for technical troubleshooting assistance before you proceed. Call 216-383-2531 or 1-800-833-9353.

CAUTION

FUNCTION PROBLEMS

PROBLEMS

(SYMPTOMS)

POSSIBLE AREAS OF

MISADJUSTMENTS(S)

RECOMMENDED

COURSE OF ACTION

The circuit breaker trips after the
wire has been feeding for a period of
time. Welding is normal.

The 1/8 amp fuse on the voltage
board repeatedly fails.

1. Check to make sure there are not

any mechanical restrictions in the
wire feeding path which could
cause excessive loading on the
wire drive motor.

1. Check to make sure the PC

boards are NOT grounded to the
case of the NA-5. This can hap-
pen due to metallic dust build-up.

1. Perform the

DC Power Supply

Test.

2. Perform the

Wire Drive Motor

Test.

3. The power board may be faulty.

1. Remove the input power to the

NA-5 and replace the 1/8 amp
fuse. Locate and remove the #21
and #67 leads from the TS1 ter-
minal strip.

A. Make a resistance check

from the following leads
to the NA-5 case ground-
ing screw. Lead #510A,
510P, 500, 515 and 525.

B. The resistances should

be above 1000 ohms. If
any tests are below 1000
ohms that circuit has low
resistance to case
ground. Isolate faulty
leads or PC board. See
wiring diagram and
schematic.