The arc is unstable or oscillating, Troubleshooting & repair, Caution – Lincoln Electric NA-5S User Manual

Page 85

Advertising
background image

F-32

TROUBLESHOOTING & REPAIR

F-32

NA-5

Observe all Safety Guidelines detailed throughout this manual

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact the Lincoln Electric
Service Department for technical troubleshooting assistance before you proceed. Call 216-383-2531 or 1-800-833-9353.

CAUTION

WELDING PROBLEMS

PROBLEMS

(SYMPTOMS)

POSSIBLE AREAS OF

MISADJUSTMENTS(S)

RECOMMENDED

COURSE OF ACTION

The arc is unstable or oscillating.

1. Check the welding cables for

loose or faulty connections.

2. Make sure the electrode and gas

(if used) is correct for the process
being used.

3. Put the output control switch (on

the power source) in the
“Machine Control” position.
Jumper the “BYPASS “ pins on
the NA-5 voltage board. Control
the arc voltage from the power
source. If the problem is NOT
remedied the power source may
be at fault. If the problem is
solved the NA-5 may be at fault.

1. The NA-5 voltage board may be

faulty. Replace.

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC