q

Unit/System SELECTION

This selection changes the Control Operation window
to that of the selected unit while communicating with
the unit.
Pull down the button to display the registered title and
PSD unit #. Select the respective unit number you wish.
The window changes to the selected unit’s where you
can control it. For example, you should select number 1
for WJ-FS416, or number 2 for WJ-HD100.

w

FRAME SWITCHER SELECT

These buttons are used to select the input image to
VIDEO IN 1-4 supplied from Video Multiplexers when a
maximum of four units are connected. In this connec-
tion example, only the button 1 performs because a
single Video Multiplexer is connected to VIDEO IN 1.

Note:

When connecting more than one Video

Multiplexer unit, you need to make selection in the
Unit/System SELECTION first, and then in the
FRAME SWITCHER SELECT.

e

CAMERA SELECT

These buttons select the input image of the camera
connected to the WJ-FS416. The selected image
appears in the Image Display area of the window.

r

MULTISCREEN SELECT

Selects a multiscreen pattern each time this button is
pressed as follows.
4

9

16

4 screen segments (WJ-FS316/416)

4

9

4 screen segments (WJ-FS309/409)

t

SEQ

Implements the sequential scan preset in the video
multiplexer. A series of camera pictures is displayed in
succession for the specific duration.

y

STILL

Displays the image in still picture. Clicking this button
again will restore the moving picture.

4. In the SERIAL PORT SETUP window, click the Unit Address SETUP page for AUX SYSTEMS to open the PS.Data Unit

Address SETUP window.
In the window, type in the device names for convenient when needed, then click the SET buttons for No. 001 through 006
to register the PS.Data devices connected to the WJ-NT204 transmitter.

Note:

When a message “No Response” appears after clicking the SET button, confirm the connections and setups described

above.

Control Operation for Video Multiplexer (WJ-FS416/409/316/309)

Type in the location bar http://192.168.0.10/ . The 192.168.0.10 in the URL may vary depending on the WJ-NT204 settings.
Type the identical address to that the WJ-NT204 is set to. FRAME SWITCHER OPERATION VIEW window appears.