Sensor in trigger out specifications – Panasonic WJ-NT204 User Manual

Page 26

Advertising
background image

26

Pin#

Name

Specification/Note

1

GND

2

TRIGGER OUT 7

Open Collector Output, Low Active, Hold Time

300 ms, Controllable Capacity 25 V DC 50 mA maximum

3

TRIGGER OUT 5

Same as TRIGGER OUT 7

4

TRIGGER OUT 3

Same as TRIGGER OUT 7

5

TRIGGER OUT 1

Same as TRIGGER OUT 7

6

SENSOR IN 8

Connect an Open Collector or non-voltage make-contact, Low Active (

0.2 V), Hold Time

100 ms,

Controllable Capacity 5 V DC maximum

7

SENSOR IN 7

Same as SENSOR IN 8

8

SENSOR IN 6

Same as SENSOR IN 8

9

SENSOR IN 5

Same as SENSOR IN 8

10

SENSOR IN 4

Same as SENSOR IN 8

11

SENSOR IN 3

Same as SENSOR IN 8

12

SENSOR IN 2

Same as SENSOR IN 8

13

SENSOR IN 1

Same as SENSOR IN 8

14

TRIGGER OUT 8

Same as TRIGGER OUT 7

15

TRIGGER OUT 6

Same as TRIGGER OUT 7

16

TRIGGER OUT 4

Same as TRIGGER OUT 7

17

TRIGGER OUT 2

Same as TRIGGER OUT 7

18-25 GND

Sensor In Trigger Out Specifications