Sensor in trigger out specifications – Panasonic WJ-NT204 User Manual
Page 26
26
Pin#
Name
Specification/Note
1
GND
2
TRIGGER OUT 7
Open Collector Output, Low Active, Hold Time
≈
300 ms, Controllable Capacity 25 V DC 50 mA maximum
3
TRIGGER OUT 5
Same as TRIGGER OUT 7
4
TRIGGER OUT 3
Same as TRIGGER OUT 7
5
TRIGGER OUT 1
Same as TRIGGER OUT 7
6
SENSOR IN 8
Connect an Open Collector or non-voltage make-contact, Low Active (
≤
0.2 V), Hold Time
≥
100 ms,
Controllable Capacity 5 V DC maximum
7
SENSOR IN 7
Same as SENSOR IN 8
8
SENSOR IN 6
Same as SENSOR IN 8
9
SENSOR IN 5
Same as SENSOR IN 8
10
SENSOR IN 4
Same as SENSOR IN 8
11
SENSOR IN 3
Same as SENSOR IN 8
12
SENSOR IN 2
Same as SENSOR IN 8
13
SENSOR IN 1
Same as SENSOR IN 8
14
TRIGGER OUT 8
Same as TRIGGER OUT 7
15
TRIGGER OUT 6
Same as TRIGGER OUT 7
16
TRIGGER OUT 4
Same as TRIGGER OUT 7
17
TRIGGER OUT 2
Same as TRIGGER OUT 7
18-25 GND
Sensor In Trigger Out Specifications