Mounting in the rack – Panasonic WJ-NT204 User Manual

Page 18

Advertising
background image

18

Remove the rubber feet.

M3 (supplied)

M3 (supplied)

• Do not block the ventilation opening or slots on the cover which prevent the appliance from overheating.

Always keep the temperature on the rack within 45°C (113°F).

• Secure the rear of the appliance to the rack using the additional mounting brackets (procured locally) if the rack is

subject to vibration.

Caution

If this switch protector is used, then it is possible to avoid the Network Interface Unit being
turned off by careless pressing of the unit POWER switch.
In case of gang power ON/OFF operation incorporated in the rack, the unit POWER switch
must always be moved to the ON position and the accessory switch protector should be
mounted.

Accessory Switch Protector

1. Loosen the four screws to remove the four rubber feet

from the bottom of the Network Interface Unit.

2. Place the rack mounting brackets on both sides of the

Network Interface Unit and tighten them with the six
supplied screws.

3. Install the Network Interface Unit with the rack mount-

ing brackets in the rack using four screws (not includ-
ed).

SWITCH

PROTECTOR

Mounting in the Rack