2. PARALLEL IN-OUT Connection

The signal inputs entering the parallel inputs 1-8 on the control site are output to the parallel outputs 1-8 on the remote site.
(Similarly, the signals entering the remote site are output to the control site.) If any one of the parallel inputs is closed, then
the corresponding parallel output is generated.
The switches connected to the control site can be used for the shut/release of the electronic lock connected to the parallel
port of the remote site via relays, etc., or for ON/OFF switching of lighting.

F

orced Disconnection

q

!4 !5 !6 !7 !8 !9 @0 @1 @2 @3 @4 @5

w e r t y u i o !0 !1 !2 !3

Mid-Comm

unication OUT

Cloc

k Adjust IN

Strobe OUT

P

a

rallel OUT 8

P

a

rallel OUT 6

P

a

rallel OUT 3

P

a

rallel OUT 1

P

a

rallel IN 8

P

a

rallel IN 6

P

a

rallel IN 4

P

a

rallel IN 2

+12 V

OUT

GND

GND

+12 V

OUT

P

a

rallel OUT 7

P

a

rallel OUT 5

P

a

rallel OUT 4

P

a

rallel OUT 2

GND

P

a

rallel IN 7

P

a

rallel IN 5

P

a

rallel IN 3

P

a

rallel IN 1

TIME

ADJUST

G

OUT

IN

1 2 3 4 5 6 7 8

BZ

Lamp

Buzzer Relay

Auxiliary Control Switch

Auxiliary Devices

BZ

Lamp

Buzzer Relay

Auxiliary Devices

Digital Disk
Recorder

Forced disconnection input terminal

Communication is forcibly finished if the making condi-
tion continues for more than 100 ms between the forced
disconnection input terminal and the nearest GND ter-
minal.

Mid-communication output terminal

When the line is connected and communication is start-
ed with the destination, this connector is closed.
There is no perfect coincidence between video or audio
and output timing. This is an open-collector output.

Strobe output terminal

When data at the parallel output connector is updated,
the strobe pulse output is generated from this connec-
tor.

Clock adjust input terminal

When this input terminal is closed, the clock incorporat-
ed in the WJ-NT204 can be corrected. The electrical
conditions are the same as those for parallel input.
Closure should be maintained for more than 100 ms.