4. Data Multiplex Unit, WJ-MP204

Set the DIP Switch on the rear of the Data Multiplex Unit
as follows.

DIP Switch Setting on the Remote Site

See the manual included in the peripheral equipment for
more information on DIP switch settings.

1. WJ-NT204

The setting shown in the figure is applied when con-
necting with PS

Data devices such as Digital Disk

Recorder, Data Multiplex Unit and Video Multiplexer on
the Remote site. The termination must be set to ON
when the unit is at the end position in the RS-485 chain,
otherwise keep it in the OFF position.

2. Digital Disk Recorder, WJ-HD100

Set the DIP Switch on the rear of the Digital Disk
Recorder as follows. Remember the RS-485 line termi-
nation rule that is the same as described above.

3. Digital Disk Recorder, WJ-HD500

Set the DIP Switch on the rear of the Digital Disk
Recorder as follows.

ON

OFF

6

5

4

3

2

1

Keep in the OFF position.

Keep in the OFF position.

RS-485 Wiring Selection

OFF: Straight, ON: Cross
(Change the ON position)

Termination for Remote Site

OFF: Open, ON: Terminate

DATA PORT Selection

OFF: RS-485, ON: RS-232C

WJ-NT204 (Transmitter)
SETUP DIP Switch

1 2 3 4

5 6

OFF

ON

Unit Address

Bit #1 #2

#3

#4

1

ON

OFF

OFF

OFF

2

OFF ON

OFF

OFF

3

ON

ON

OFF

OFF

RS-485 Termination

OFF:Open, ON:Terminate

Digital Disk Recorder
WJ-HD100

ON

OFF

Sync Out (VS/VD) Selection
OFF: Looped Through, ON: Internal VD

Termination
OFF: Open, ON: Terminate

Data Line Selection
OFF: 4-Line, ON: 2-Line

Data Communication Mode Bit #3

#4

PS.Data

OFF

OFF

Camera Mode

ON

OFF

Data Multiplex Unit

1 2 3 4

5 6

ON

OFF

Digital Disk Recorder
WJ-HD500