Serial port setup – Panasonic WJ-NT204 User Manual

Page 85

Advertising
background image

86

SERIAL PORT SETUP

On the

ADMINISTRATOR SETUP PAGE

, click the

SERIAL PORT

button to display the

SERIAL PORT SETUP

window.

Specify whether to use the RS-232C or RS-485 interface, and set the communication parameters.
Make certain that the DIP switch #4 on the rear of the transmitter is set to OFF when the RS-485 port is used, or to ON when the
RS-232C port is used.

q

TYPE

Specify a peripheral device that communicates with the
transmitter through the serial port. Click the ▼ button
repeatedly to scroll down the options shown below.
The default setting is PS

Data.

The following options are available when DIP switch #4 is
set to OFF (RS-485 ) on the rear of the WJ-NT204.

WJ-SX550A/B:

Matrix Switcher System

WJ-FS616:

Video Multiplexer

PS.Data:

Products capable of Panasonic Security Data

protocol

Serial Through:

Data is transmitted through the DATA

port using comthr.html.

The following options are available when DIP switch #4 is
set to ON (RS-232C ) on the rear of the WJ-NT204.

WJ-SX550A/B:

Matrix Switcher System

WJ-SX850:

System 850 Matrix Switcher

WJ-DR200:

Digital Disc Recorder

Serial Through:

Data is transmitted through the DATA

port using comthr.html.

w

BAUD RATE

Set the rate to 4 800, 9 600 or 19 200 bps. The default
setting is 9 600 bps.

e

DATA BIT

Set the data bit to 7 or 8 bits. The default is 8 bits.

r

STOP BIT

Set the stop bit to 1 or 2 bits. The default is 1 bit.

t

PARITY

Set the parity check to NONE, ODD or EVEN. The
default setting is NONE.

y

WAIT TIME

Set the wait time with the ▼ button. The default setting

is OFF.

u

UNIT ADDRESS

Set an address number within 002 through 999 when
TYPE is set to PS

Data. The default setting is 002.

Notes:

Special caution should be used for setting unit

address when the System Controller WV-CU360 is
installed in the system.

• The transmitter WJ-NT204 will be set to address

“1” automatically, when no receiver WJ-NT204 is
connected to the transmitter except the PC. The
WV-CU360 connected to the transmitter should be
set to other than “1”.

• The transmitter WJ-NT204 will be set to the

address by this operation, when a receiver WJ-
NT204 is connected. The Control site WV-CU360
connected to the receiver should be set to “1”
while the Remote site WV-CU360 be set to other
than “1” and “ transmitter’s address”.

i

GROUP ADDRESS

Set an address within 00A through 00Z. The default
setting is 00A.

o

PS.Data Unit Address SETUP

Is linked to the PS.Data Unit Address SETUP page.

!0

WJ-DR200 SETUP

Set the CONTROL PRIORITY from among three
options. The default setting is AUTOMATICALLY
CHANGE OVER.

!1

WJ-SX550A/B and WJ-SX850 MATRIX SWITCHER

SETUP

Clicking on this line will open the WJ-SX550A/B and
WJ-SX850 MATRIX SWITCHER setup window.

q

y

u

i

o

!0

w

r

e

t

!1

Advertising