o

ALARM TYPE

This setting specifies the sensor (alarm) input reception
whether to accept or ignore depending on the signal
forms, and applies to all 8 inputs on the rear of the
transmitter. The default setting is EDGE (CLOSE).

LEVEL:

The transmitter enters the alarm mode when

the input retains active (when low) for more than 1
second.

EDGE (OPEN):

The transmitter enters the alarm mode

when the input changes from close to open.

EDGE (CLOSE):

The transmitter enters the alarm mode

when the input changes from open to close.

Note:

The alarm log may record redundant event when

this setting is changed from one to another.

!0

ALARM PORT Enable/Disable SETUP page

Clicking this line opens the setup page.

The sensor inputs connected to the rear of the transmit-
ter unit can be enabled or disabled with this setup. EXT
can be set only for the port #8. This setup is applied
only to the transmitter unit. The default setting is
ENABLE for all ports.

ENABLE:

The unit accepts the sensor input.

DISABLE:

The unit ignores the sensor input.

EXT:

The highest priority is given to #8 port that the

unit ignores inputs to other ports when #8 port is
activated.

!1

ALARM LOG CLEAR

Click this button to clear the alarm log.