- 144 –

Cable Length test.

Figure 4-73

Cable Test screen

The page contains the following fields:

Port

This is the port to which the cable is connected.

Test Result

OK - indicates that the cable passed the test.

No Cable - means no cable connected to the port.

Open Cable -means the cable is connected on only one side.

Short Cable - indicates that a short has occurred in the cable.

Cable Fault Distance This is the distance from the port at which the cable error occurred

Last Update

This is the last time the port was tested

Cable Length

This is the approximate length of the cable.

The Cable Length test can be performed only when the port is up and
operating at 1Gbps

4.12.7 Save Configuration

On this screen, you can choose two methods to save the configuration: Via TFTP Upgrade and Via HTTP. See figure 4-74