6 show rmon alarm-table, Default configuration, Command mode – Planet Technology WGSD-8000 User Manual

Page 281: User guidelines, Example, Syntax

Advertising
background image

User’s Manual of WGSD-1022/WGSD-8000

- 281 –

ƒ

startup direction — The alarm that may be sent when this entry is first set to valid. If the first sample (after this entry

becomes valid) is greater than or equal to the rthreshold, and direction is equal to rising or rising-falling, then a single

rising alarm is generated. If the first sample (after this entry becomes valid) is less than or equal to the fthreshold, and

direction

is equal to falling or rising-falling, then a single falling alarm is generated.

ƒ

owner name — Enter a name that specifies who configured this alarm. If unspecified, the name is an empty string.

Default Configuration

The following parameters have the following default values:

type type

— If unspecified, the type is absolute.

startup direction

— If unspecified, the startup direction is rising-falling.

Command Mode

Global Configuration mode

User Guidelines

There are no user guidelines for this command.

Example

The following example configures the following alarm conditions:

ƒ

Alarm index — 1000

ƒ

Variable identifier — abc

ƒ

Sample interval — 360000 seconds

ƒ

Rising threshold — 1000000

ƒ

Falling threshold — 1000000

ƒ

Rising threshold event index — 10

ƒ

Falling threshold event index — 20

Console (config)# rmon alarm 1000 abc 360000 1000000 1000000 10 20

5.19.6 show rmon alarm-table

The show rmon alarm-table user EXEC command displays the alarms summary table.

Syntax

show rmon alarm-table

Default Configuration

This command has no default configuration.