3. Configuration

3-72

April

2002

9128-A2-GB20-60

Source EDLCI

Possible Settings: 0 – 62
Default Setting: Initially blank; no default.

Specifies the source Embedded Data Link Connection Identifier (EDLCI) for a frame relay
interface when a multiplexed DLCI record is selected as one end of a connection.

Display Conditions

– This option only appears when Source DLCI contains a

multiplexed DLCI record number.

0 – 62 – Specifies the EDLCI number.

Primary Destination Link

Possible Settings: Net1-FR1,

ISDN Link Name

Default Setting: Initially blank; no default.

Specifies the frame relay interface used as the primary destination link; the to end of a
from-to link. The only valid settings for this configuration option are frame relay interfaces
that have at least one DLCI or EDLCI defined which are not part of a PVC connection or
management link. For example, if the network interface has no DLCIs defined, Net1-FR1
would not appear as a valid setting.

Net1-FR1 – Specifies the Network interface as the destination link.

ISDN Link Name

– For units with ISDN backup capability, specifies the ISDN link of the

DBM as the destination of the connection. This can be any nonnull link name configured
on an ISDN frame relay link.

Primary Destination DLCI

Possible Settings: 16 – 1007
Default Setting: Initially blank; no default.

Specifies the primary destination DLCI for a frame relay interface. The DLCI must be
defined and cannot be part of a PVC connection or management link. For multiplexed
DLCIs, at least one EDLCI must be unconnected for the DLCI to be a valid selection.

NOTES:

– Primary Destination DLCI has no value if Primary Destination Link contains no

value.

– When an ISDN DBM is installed and the DLCI assigned to the PVC is in a Backup

Group (see

Table 3-14, DLCI Record Options

), the letter designation assigned to

the group of DLCIs appears next to the primary destination DLCI number on the
Management PVCs Options screen.

16 – 1007 – Specifies the DLCI number.

Table 3-15. PVC Connection Options (2 of 4)