Viewing the trap event log, Troubleshooting tables, Device problems – Paradyne 9128-II User Manual

Page 250

Advertising
background image

6. Troubleshooting

6-14

April

2002

9128-A2-GB20-60

Viewing the Trap Event Log

The Trap Event Log displays all traps stored in the SNMP trap event log. ASCII
trap strings used to describe trap events are provided in the tables contained in
Standards Compliance for SNMP Traps (see

Appendix B,

SNMP MIBs and Traps,

and RMON Alarm Defaults

).

See

Trap Event Log

in Chapter 5,

Operation and Maintenance, for a screen

example and additional information.

Troubleshooting Tables

The unit is designed to provide many years of trouble-free service. However, if a
problem occurs, refer to the appropriate table in the following sections for possible
solutions.

Device Problems

Table 6-2.

Device Problems (1 of 2)

Symptom

Possible Cause

Solutions

No power, or the LEDs
are not lit.

The power cord is not
securely plugged into the
wall receptacle to rear panel
connection.

Check that the power cord is
securely attached at both ends.

The wall receptacle has no
power.

T

Check the wall receptacle
power by plugging in some
equipment that is known to be
working.

T

Check the circuit breaker.

T

Verify that your site is not on an
energy management program.

Power-On Self-Test
fails. Only Alarm LED
is on after power-on.

The unit has detected an
internal hardware failure.

T

Reset the unit and try again.

T

Contact your service
representative.

T

Return the unit to the factory
(refer to

Warranty, Sales,

Service, and Training
Information

on page A of this

document).

Advertising
This manual is related to the following products: