B. SNMP MIBs and Traps, and RMON Alarm Defaults

9128-A2-GB20-60

April 2002

B-15

enterpriseSelfTest-
Fail(2)

T

devLastTrapString
(devHealthAndStatus.-
mib)

Unit has completed
(re)initialization and a hardware
failure was detected.

String:

‘Self test failed: $

s

.’ ($

s

is the

contents of devSelfTestResult.)

enterpriseTest-
Start(5)

For physical interfaces and
frame relay links:

T

ifIndex (RFC 1573)

T

.0.0 (placeholder)

T

devLastTrapString
(devHealthAndStatus.-
mib

For virtual circuits (DLCIs):

T

devFrExtDlciIfIndex
(devFrExt.mib)

T

devFrExtDlciDlci
(devFrExt.mib)

T

devLastTrapString
(devHealthAndStatus.-
mib

At least one test has been started
on an interface or virtual circuit.

String:

‘$testString test started on
$ifString.’ (e.g., ‘DTE Loopback
test started on Sync Data Port
S01P1.’)

enterpriseTest-
Stop(105)

All tests have been halted on an
interface or virtual circuit.

String:

‘$testString test stopped on
$ifString.’ (e.g., ‘Disruptive PVC
Loopback test stopped on DLCI
100 of Sync Data Port S01P1
frame relay.’)

Table B-7.

enterprise-Specific Traps and Variable-Bindings (3 of 3)

Trap

Variable-Bindings