Clearing assignments – Paradyne 9128-II User Manual

Page 98

Advertising
background image

3. Configuration

3-64

April

2002

9128-A2-GB20-60

For easy movement between screens, select the FrAssign function key to go
directly to the Frame Relay Network Assignments screen or the DSXAssign
function key to go to the DSX-1 to Network Assignments screen.

Time Slot Assignment Rules:

T

To assign a synchronous data port to network or DSX-1 time slots, Port-2’s
Port Use option must be set for Synchronous Data (see

Table 3-7, Data Port

Physical Interface Options

).

T

If the DSX-1 interface is disabled, only Net1 is available for synchronous data
port assignment (see the Interface Status option in

Table 3-8, DSX-1 Physical

Interface Options

).

Procedure

1. Select one of the following menu selection sequences:

Main Menu

Configuration

Time Slot Assignment

Sync Data Port Assignments or

Main Menu

Easy Install

Time Slot Assignment Screen

2. Select an interface in the Assign To field. A matrix of the current cross-connect

status of all time slots on the selected interface appears.

3. Move the cursor to the next time slot that can be edited (underlined). Use the

spacebar or type in the desired time slot to display its time slot assignment.

4. Repeat Step 3 until the synchronous data port is assigned to all desired time

slots.

5. Save the configuration.

Clearing Assignments

Clearing assignments sets all time slots to Unassgn (unassigned).

Main Menu

Configuration

Time Slot Assignment

Clear Assignments