Table 5-2, network, dsx, or pri interface leds, Table 5-3, user data port led – Paradyne 9128-II User Manual

Page 166

Advertising
background image

5. Operation and Maintenance

5-10

April

2002

9128-A2-GB20-60

Table 5-2.

Network, DSX, or PRI Interface LEDs

Label

Indication

Color

What It Means

SIG Signal

Green

ON

– A recoverable signal is present on the

Network/DSX/PRI interface.

OFF – The signal cannot be recovered from the
Network/DSX/PRI interface. An LOS condition
exists.

OOF

Out of Frame

Yellow

ON – At least one OOF was detected during the
sampling period.

OFF – No OOFs were detected during the
sampling period.

ALM

Alarm

Yellow

ON – An alarm condition is present on the
network/DSX/PRI interface.

Current alarm conditions:

T

Loss of Signal ( LOS)

T

Loss of Frame (LOF)

T

Out of Frame (OOF)

T

Excessive Error Rate (EER)

T

Yellow Alarm Signal

T

Alarm Indication Signal (AIS)

OFF – No alarm condition is present on the
Network/DSX/PRI interface.

Table 5-3.

User Data Port LED

Label

Indication

Color

What It Means

OK

1

Operational
Status

Green

ON – The interchange circuits for the port are in
the correct state to transmit and receive data.

OFF – The port is idle. Occurs if the port is
disabled, or if the port is configured to monitor
DTR and/or RTS and the lead(s) is not asserted.

1

The FrameSaver SLV 9128-II only has one OK LED even though it has two user
data ports. If either port is enabled and active, the LED is on. If both ports are
enabled and one of the ports is inactive, the LED is off.