3. Configuration

9128-A2-GB20-60

April 2002

3-39

Line Build Out (LBO)

Possible Settings: 0.0, –7.5, –15, –22.5
Default Setting: 0.0

Specifies the line build out for the signal transmitted to the network.

0.0, –7.5, –15, –22.5 – Specifies line build out in dB.

Bit Stuffing

Possible Settings: 62411, Disable
Default Setting: 62411

Determines the type of bit insertion to provide ones density requirements for data
transmitted to the network.

Display Conditions

– This option does not appear when Line Coding Format is set to

B8ZS.

62411 – Inserts a one in the data after 15 consecutive zeros are received or the density of
ones falls below 12.5%. This setting complies with AT&T TR 62411, but is not
recommended for frame relay data because it inserts errors in the data traffic.

Disable – Disables bit stuffing. Ones density is not enforced on data sent to the network.

Transmit Timing

Possible Settings: System, Interface
Default Setting: System

Allows transmit timing to be selected from either the system master clock source or from
the currently selected interface.

System – Transmit timing is derived from the current system clock source (see

Table 3-5,

General System Options

).

Interface – Transmit timing is derived from this interface.

NOTE: When Interface is configured, the clock must be synchronized to the system
clock source.

Network Initiated LLB

Possible Settings: Enable, Disable
Default Setting: Enable

Allows the initiation and termination of the line loopback (LLB) to be controlled by the
receipt of LLB-Actuate and LLB-Release commands from the network.

Enable – LLB is controlled by LLB-Actuate and LLB-Release commands. Receiving a
LLB-Actuate command causes the FrameSaver unit to enter a line loopback (provided an
LLB can be performed in the FrameSaver unit’s current state). Receiving an LLB-Release
command terminates the LLB.

Disable – The FrameSaver unit ignores the LLB-Actuate and LLB-Release commands.

NOTE: When disabled, the system is not in compliance with ANSI T1.403 or
AT&T TR 62411.

Table 3-6.