6. Troubleshooting

6-24

April

2002

9128-A2-GB20-60

Send Pattern

This test sends packets filled with a hexadecimal 55 test pattern and sequence
number over the selected interface and DLCI to another FrameSaver device.

To send a pattern test on a link:

Main Menu

Test

[Network PVC Tests/Data Port PVC Tests/

ISDN Call/PVC Tests]

If the CIR is zero, the pattern will be sent at a rate of 1000 bps.

Monitor Pattern

This test monitors packets filled with a hexadecimal 55 test pattern and sequence
number over the selected interface and DLCI to another FrameSaver device.

To monitor a pattern test on a link:

Main Menu

Test

[Network PVC Tests/Data Port PVC Tests/

ISDN Call/PVC Tests]

The current number of sequence and data errors are shown under the Result
column when the

FrameSaver unit is in sync. An

Out of Sync

message appears

when 5 frames out of 25 are missing or out of sequence.

These error counts are updated every second. If the maximum count is reached,

99999+

appears in these fields.

If the selected DLCI is
configured as . . .

Then . . .

And the default
Rate (Kbps) setting is . . .

Standard

(Disruptive)

appears

after Test

100% of CIR

Multiplexed

(Non-Disruptive)

appears after Test

10% of CIR