B. SNMP MIBs and Traps, and RMON Alarm Defaults

9128-A2-GB20-60

April 2002

B-11

Table B-6.

linkUp and linkDown Variable-Bindings (1 of 2)

Interface

Variable-Bindings

Possible Cause

Physical Sublayer

T1 Network,
DSX-1,
PRI

(Supported by the
media-specific DS1
MIB.)

T

ifIndex (RFC 1573)

T

ifAdminStatus (RFC
1573)

T

ifOperStatus (RFC 1573)

T

devLastTrapString
(devHealthAndStatus.-

mib)

T

linkDown – One or more alarm
conditions are active on the
interface.

Alarm conditions include:

– Loss of Signal (LOS) or

far-end loss of signal

– Out of Frame (OOF)

– Alarm Indication Signal

(AIS)

– Excessive Error Rate (EER)

– Yellow Alarm

Strings:

‘$ifString down.’ No alarms
exist. (e.g., ‘Network T1 down
due to yellow alarm.’ )

‘$ifString administratively
shutdown.’ (Due to an
intentional shutdown.)

T

linkUp – No alarms on the
interface.

String:

‘$ifString up.’

Synchronous Data
Port

(Supported by the
media-specific
RS232-like MIB.)

T

ifIndex (RFC 1573)

T

ifAdminStatus
(RFC 1573)

T

ifOperStatus (RFC 1573)

T

devLastTrapString
(devHealthAndStatus.-

mib)

T

linkDown – One or more alarm
conditions are active on the
port.

Alarm conditions include:

– DTR off

1

– RTS off

2

– ‘ ’ – Not DTR or RTS, but

link is down.

String:

‘$ifString $alarmString down.’
(e.g., ‘Sync Data Port S01P1
DTR and RTS down.’)

‘$ifString administratively
shutdown.’ (Due to an
intentional shutdown.)

T

linkUp – No alarms on the port.

String:

‘$ifString up.’

1

The DTR alarm condition will only generate a linkUp/ linkDown trap if the DTE
supports the DTR lead state.

2

The RTS alarm condition will only generate a linkUp/ linkDown trap if the DTE
supports the RTS lead state.

3

If the LMI Protocol is not configured, a linkUp/linkDown trap is based solely upon

whether the interface is enabled or disabled.