Paradyne 9128-II User Manual

Page 91

Advertising
background image

3. Configuration

9128-A2-GB20-60

April 2002

3-57

Time Slot Assignment Rule:

Valid network time slots are either Available or contain a Frame Relay Link 1
assignment.

Procedure

1. Follow this menu selection sequence:

Main Menu

Configuration

Time Slot Assignment

Frame Relay Network Assignments

The Frame Relay Network Assignments screen appears. This screen contains
a matrix of the current assignment status of all time slots on the network
interface.

2. Enable or disable Time Slot Discovery.

— When enabled, the unit examines all time slots not cross-connected to

other ports to determine which time slots are being used by the network
for frame relay traffic. These time slots are set to FrameRly1. This is the
factory default.

— When disabled, time slot assignments must be manually configured.

3. If Time Slot Discovery is disabled, assign network time slots for use by frame

relay service, link 1, by typing FrameRly1 in the selected Network field.

4. Repeat Step 3 until all desired time slots are assigned.

5. Save the configuration.

Assigning DSX-1 Time Slots to the Network Interface

DSX-1 time slots are assigned by channel allocation, where you specify individual
time slots. The DSX-1 interface must be enabled to assign DSX-1 time slots to the
network interface (see

Table 3-8, DSX-1 Physical Interface Options

).

Value

Meaning

N

tt

It represents time slot

tt

of the selected network interface.

Assigned

The time slot is already assigned to something other than a DSX-1
time slot, so it is unavailable. Assigned time slots cannot be modified
from this screen.

Available

The time slot is currently unassigned.

DSX-1/

tt

Slot

tt

of the DSX-1 interface is assigned to the network interface

time slot identified right above it (N

tt

).

Advertising