Clearing performance statistics – Paradyne 9128-II User Manual

Page 207

Advertising
background image

5. Operation and Maintenance

9128-A2-GB20-60

April 2002

5-51

Clearing Performance Statistics

Performance statistics counters can be reset to the baseline when using a
directly-connected asynchronous terminal and your security Access Level is
Level-1. This feature is useful when troubleshooting problems.

Statistic counters are not actually cleared using this feature. True statistic counts
are always maintained so SLAs can be verified, and they can be viewed from an
SNMP NMS. However, since statistics can be cleared locally, the statistics viewed
via the menu-driven user interface may be different from those viewed from the
NMS.

Procedure

To clear all statistics:

Performance Statistics

Clear All Statistics

Procedure

To clear specific sets of statistics:

T

Use the Cl rSLV&DLCIStats function key to reset the SLV and DLCI
performance statistic counters for the currently displayed DLCI from one of the
following screens:

Performance Statistics

Service Level Verification

Performance Statistics

DLCI

T

Use the Cl rLinkStats function key to reset the frame relay link performance
statistics.

Performance Statistics

Frame Relay

T

Use the Cl rNearStats or C l rFarStats function key to reset all near-end or all
far-end Extended SuperFrame (ESF) line performance statistics.

Performance Statistics

ESF Line

T

Use the Cl rDBMStats function key to reset the DBM call performance
statistics.

Performance Statistics

DBM Call

T

Use the Cl rStats function key to reset all Ethernet port performance statistics.

Performance Statistics

Ethernet

Advertising
This manual is related to the following products: