5. Operation and Maintenance

5-8

April

2002

9128-A2-GB20-60

LED Descriptions

Table 5-1, General Status LEDs

, identifies the alarms that cause the Alarm LED to

light. See

Table 5-2, Network, DSX, or PRI Interface LEDs

, for network, DSX-1, or

PRI interface LED and

Table 5-3, User Data Port LED

, for user data port interface

LED information.

Table 5-1.

General Status LEDs (1 of 2)

Label

Indiction

Color

What It Means

OK

1

Power and
Operational
Status

Green

ON – FrameSaver unit has power and it is
operational.

OFF – FrameSaver unit is in a power-on
self-test, or there is a failure.

ALM Operational

Alarm ( Fail)

Red

ON – FrameSaver unit has just been reset, or an
error or fault has been detected.

Error/fault/alarm conditions:

T

Alarm Indication Signal (AIS)

T

CTS Down

T

DBM BRI Card Failure

T

DBM Download Failed

T

DLCI Down

T

DTR Down

T

Ethernet Link Down

T

Exceeded Error Rate (EER)

T

Internal Modem Failed

T

ISDN Network Failed

T

LMI Down

T

Loss of Signal (LOS)

T

Network Communication Link Down

T

Out of Frame ( OOF)

T

Power Supply/Fan Failure

T

Primary or Secondary Clock Failed

T

Self-Test Failed

T

SLV Latency Exceeded

T

SLV Timeout

T

Suboptimal Link Rate

T

Two Level-1 Users Accessing Device

T

Yellow Alarm Signal

1

When an ISDN BRI DBM is installed, if the OK LED comes on then goes off during
power recycling, the ISDN BRI DBM may have failed.

2

On the Display LEDs & Control Leads screen for the Model 9128-II only, FR Mode
is On or Off. When On (highlighted), the FrameSaver unit is in Frame Relay mode.