Paradyne 9128-II User Manual

Page 177

Advertising
background image

5. Operation and Maintenance

9128-A2-GB20-60

April 2002

5-21

DBM Download Required

(ISDN BRI DBM only)

A download attempt was interrupted and failed to
complete.

The NAM software and DBM software are
incompatible.

DCLB Active,

[Interface]

A V.54 Loopback is active on the specified interface.

DLCI

nnnn

Down,

frame relay link

1,2

The DLCI for the specified frame relay link is down.

DTE External LB Active, Port-

n

A Data Terminal Loopback is running on the
specified user data port.

DTE Init. Ext LB Active, Port-

n

The DTE has initiated an external DTE Loopback on
the specified user data port.

DTPLB Active, Port-2

A Data Terminal Payload Loopback (DTPLB) is
active on the synchronous user data port.

DTR Down from Port-1 Device

The DTR control lead from the device connected to
the user data port is deasserted.

EER at ISDN PRI (Active/Idle)

(ISDN PRI DBM only)

The error rate of the received ISDN network signal
exceeds the currently configured threshold. This
condition only occurs if the network interface is
configured for ESF framing and a PRI dial backup
module (DBM) is installed.

T

Active – Backup call was in progress.

T

Idle – DBM was in Idle mode.

This condition clears when the error rate falls below
the threshold value, which may take up to
15 minutes.

EER at Network

1

The error rate of the received network signal exceeds
the currently configured threshold. This condition
only occurs if the network interface is configured for
ESF framing.

This condition clears when the error rate falls below
the threshold value, which may take up to
15 minutes.

Ethernet Link Down

(FrameSaver SLV 9126-A2 or
9128-II)

The Ethernet port is enabled, but communication
between the management system and the unit is not
currently possible on the port.

Internal Modem Failed

The unit’s internal modem failed to pass the self-test.

ISDN Active

An ISDN call is active.

Table 5-7.

Health and Status Messages (2 of 7)

Message

What It Indicates

1

nnnn

indicates a DLCI number of 16 through 1007.

2

frame relay link

is one of the following:

– Net1-FR1. The frame relay link specified for the network interface, Network 1.
– Port-

n

. The frame relay link associated with the user data port.

ISDN Link Name

on a non-network ISDN DBM interface.

3

Does not apply to a TS Management Link DLCI.

Advertising
This manual is related to the following products: