5. Operation and Maintenance

9128-A2-GB20-60

April 2002

5-15

No DLCIs Available for
Mgmt PVC

New was selected from the
Management PVCs option
screen, but all configured
DLCIs have been
connected.

Configure more network and/or
Port-1 DLCIs and try again.

No DLCIs Defined

DLCI Records was selected
from an interface’s
Configuration Edit/Display
menu, and no DLCI
Records have been created
for this interface.

Select New and create a DLCI
record.

No more DLCIs
allowed

New or CopyFrom was
selected from an interface’s
DLCI Records configuration
screen, and the maximum
number of DLCI Records
had already been reached.

Delete a DLCI, then create the
new DLCI Record.

No Primary
Destination Link DLCIs
Available

New or Modify was selected
from the PVC Connection
Table, but even though
DLCIs are available to form
a connection, no DLCIs are
available on the network
link, which is a suitable
Primary PVC Destination.

Configure additional DLCIs for the
network link and try again.

If a network DLCI has been
entered as a Source DLCI:

1. Change the Source DLCI to a

user data port DLCI.

2. Enter the network DLCI as the

PVC’s Primary Destination.

No Security Records
to Delete

Delete was selected from
the Administer Login
screen, and no security
records had been defined.

T

No action needed.

T

Enter a security record.

Password Matching
Error – Re-enter
Password

Password entered in the
Re-enter Password field of
the Administer Logins
screen does not match what
was entered in the
Password field.

T

Try again.

T

Contact your system
administrator to verify your
password.

Permission Denied

(Seen at an FTP
terminal.)

A file transfer was
attempted, but the:

T

User did not have Level
1 security.

T

Wrong file was specified
when the put command
was entered.

T

User attempted to
upload a program file
from the unit.

T

See your system administrator
to get your security level
changed.

T

Try again, entering the correct
file with the put command.

T

Enter the put command
instead of a get command; you
can only transfer files to the
unit, not from it.

See

Upgrading System

Software

on page 5-76.

Table 5-5.

Device Messages (4 of 6)

Message

What It Indicates

What To Do

Advertising