5. Operation and Maintenance

5-80

April

2002

9128-A2-GB20-60

Turning Off the System Alarm Relay

For carrier-mounted FrameSaver units, an alarm system relay is provided by the
9000 Series Access Carrier. This relay activates a light or buzzer when an alarm
condition is detected in one of the FrameSaver units.

Once the alarm relay is connected, enabling the System Alarm Relay option
activates this feature (see

Table 3-5, General System Options,

in Chapter 3,

Configuration).

Once activated, the relay is turned off in one of the following ways:

T

The alarm condition that activated the relay no longer exists. The relay stays
on until all alarm conditions have been corrected.

T

The System Alarm Relay option can be disabled.

Main Menu

Configuration

System

General

T

System Alarm Relay Cut-Off can be selected.

Main Menu

Control

System Alarm Relay Cut-Off

See

Alarm Relay Connector in the

9000 Series Access Carrier Installation

Instructions

for information about connecting the alarm relay.