3. Configuration

9128-A2-GB20-60

April 2002

3-17

Setting Up Dial Backup

When configuring units with ISDN backup capability, the following guidelines
apply:

T

Central site configuration guidelines:

— Set up the ISDN DBM physical interface.

— If a BRI DBM, change the Automatic Backup Configuration to

Multi_Site_Backup. (A PRI DBM is already configured for multisite
backup.)

— Modify the Link Profile(s) that Automatic Backup Configuration created to

add a phone number.

T

Remote site configuration guidelines:

— Set up the ISDN DBM physical interface.

— If a PRI DBM, change the Automatic Backup Configuration to

Single_Site_Backup. (A BRI DBM is already configured for single-site
backup.)

— Modify the HQ_Site Link Profile that Automatic Backup Configuration

created to add a phone number.

— Set the criteria by which automatic backup will take place.

Setting Up the DBM Physical Interface

Procedure

1. Configure the DBM interface.

Main Menu

Configuration

ISDN

Physical

2. Enable the interface, and enter the Service Profile IDs (SPIDs) and local

phone numbers.

3. Save the configuration.

See

Table 3-9, ISDN BRI DBM Physical Interface Options

, or

Table 3-10, ISDN

PRI DBM Physical Interface Options

, for configuration information.